Results 51 to 60 of about 1,817 (183)

An Overview of High‐Temperature Superconducting Cables in DC Systems: Unlocking Potential for High‐Voltage DC Networks

open access: yesHigh Voltage, EarlyView.
ABSTRACT This paper provides an overview of high‐temperature superconducting (HTS) cables in DC systems, with a focus on their deployment in high‐voltage DC (HVDC) networks. The assessment of HTS cable properties—such as extremely low electrical resistance, high current‐carrying capacity and a compact geometry—and their comparison with those of ...
Mohammad Hossein Mousavi   +2 more
wiley   +1 more source

Proposing a Rule for VSC-HVDC Optimal Placement to Improve Transient Stability of Power System [PDF]

open access: yesInternational Journal of Research and Technology in Electrical Industry
Transient stability indicates the system's ability to dampen the rotor oscillations of synchronous generators after severe faults. The transient instability causes considerable damage to the generator and reduces the production capacity in the network ...
Ali Abrishami Moghaddam   +2 more
doaj   +1 more source

Ion‐Flow Field Modelling of ± 1100 kV Transmission Lines Under Strong‐Wind Scenarios Using the Multiple Relaxation Time Lattice Boltzmann Method

open access: yesHigh Voltage, EarlyView.
ABSTRACT To solve the ion‐flow field of ultrahigh‐voltage direct current (UHVDC) transmission lines under strong‐wind scenarios, the multiple relaxation time lattice Boltzmann method (MRT‐LBM) is adopted. Compared with previous ion‐flow studies predominantly based on the single relaxation time LBM, the MRT‐LBM framework provides improved numerical ...
Ting Zhu, Rongbin Wang, Haidong Wang
wiley   +1 more source

Current‐Carrying Characteristics of High‐Voltage Land Cables With Different Grounding Methods for Low‐Frequency AC Transmission

open access: yesHigh Voltage, EarlyView.
ABSTRACT Low‐frequency AC transmission holds promise for high‐voltage land cables, but its ampacity is significantly influenced by cable grounding methods and other structural factors. To explore the specific low‐frequency current‐carrying characteristics of high‐voltage land cables, this paper conducts a thorough theoretical analysis of the coupling ...
Yongpei Li   +4 more
wiley   +1 more source

Recyclable insulation material for HVDC cables in Global Energy Interconnection

open access: yesGlobal Energy Interconnection, 2018
With the development of modern power systems, especially that of the global energy internet, high-voltage, direct current (HVDC) cable power transmission will play an important role in the future.
Yao Zhou   +4 more
doaj   +1 more source

Optimization of Wind‐PV Co‐Generation Systems Using Artificial Bee Colony and Back‐to‐Back Voltage Source Converter

open access: yesIET Smart Energy Systems, EarlyView.
The Graphical Abstract depicts the proposed Artificial Bee Colony algorithm‐based optimal tuning of PI controllers for back‐to‐back Voltage Source Converters in a hybrid wind–PV system. ABSTRACT This paper proposes a hybrid model‐based back‐to‐back voltage‐source converter (B2B‐VSC) system comprising a Photovoltaic (PV) array and a Permanent Magnet ...
Ch. Sreenu   +3 more
wiley   +1 more source

Dynamic Covalent Chemistry Enables Self‐Healing and Compatibilization in Polypropylene Composites

open access: yesENERGY &ENVIRONMENTAL MATERIALS, Volume 9, Issue 5, September 2026.
A high‐performance polypropylene insulation material is created through dynamic covalent crosslinking. It achieves exceptional dielectric properties, autonomous self‐healing, and easy recycling, offering a sustainable solution for future HVDC transmission systems.
Hongzhe Zhang   +3 more
wiley   +1 more source

Characteristics of electrostatic discharges between metallic objects in the ion-flow field under HVDC lines

open access: yesThe Journal of Engineering, 2019
Metallic objects under high-voltage direct current (HVDC) transmission lines will produce certain induced voltages due to the charging of ion flow. Electrostatic discharge (ESD) may occur between two objects at different potentials when they are close ...
Xueshan Li, Donglai Wang, Tiebing Lu
doaj   +1 more source

A Review of Overcurrent Protection in Smart Grids Under Cyber‐Physical Threats With a Cyber‐Physical Evaluation Framework

open access: yesEnergy Science &Engineering, Volume 14, Issue 8, Page 3948-3973, August 2026.
By manipulating current and voltage measurements, an assailant can induce unwanted relay action while attempting to avoid detection. Detecting advanced cyber intrusions in power protection environments requires specialised data analysis and anomaly detection methods.
Feras Alasali   +6 more
wiley   +1 more source

A Study for the Measurement of the Minimum Clearance Distance between the 500 kV DC Transmission Line and Vegetation

open access: yesEnergies, 2018
High voltage direct current (HVDC) transmission is being widely implemented for long-distance electrical power transmission due to its specific benefits over high voltage alternating current (HVAC) transmission.
Kumail Hassan Kharal   +6 more
doaj   +1 more source

Home - About - Disclaimer - Privacy