Results 61 to 70 of about 1,817 (183)
HVDC Transmission with STATCOM
Most of the HVDC power converters with thyristor valves are assembled in a converter Bridge of Six pulse configuration. Converter transformers with one DC side winding as an ungrounded star connection and the other a delta configuration. Comparative studies of the two systems of HVDC CIGRE model without STATCOM and with STATCOM were performed. In these
openaire +1 more source
During regular operation of the SuedLink at a load ≤75 %, the average increase in temperature in the plowing horizon is expected to be less than 1.6°C in the soils along the route in Southwest Germany. ABSTRACT Background The SuedLink was planned as a high‐voltage direct‐current underground cable route. The construction itself is a massive intervention
Joachim Ingwersen +10 more
wiley +1 more source
This work introduces an IGSA‐BPSO optimized hybrid PIDNPDN controller for Automatic Generation Control in deregulated multisource power systems with electric vehicle integration, achieving faster dynamic response, reduced settling times, and enhanced stability compared to conventional controllers, thereby improving system reliability, flexibility, and ...
Ajay Kumar +3 more
wiley +1 more source
Simulation of GIC in the North Island of Aotearoa New Zealand Based on Magnetotelluric Measurements
Abstract New magnetotelluric (MT) data, combined with older MT data are used to simulate geomagnetically induced currents (GIC) in the power network of the North Island of Aotearoa New Zealand for two geomagnetic storms. For the May 2024 G5 Gannon Storm, simulations use magnetic field data from two separate locations—the Intermagnet geomagnetic ...
K. M. Pratscher +6 more
wiley +1 more source
HVDC Circuit Breaker Development and Applications in VSC-HVDC Transmission Project
Abstract High voltage direct current (HVDC), especially voltage source based HVDC (VSC-HVDC), transmission technology has been expanding in recent decades. HVDC circuit breaker therefore attracts significant interest due to its abilities of current interruption and fault isolation.
Yuefeng Yang +5 more
openaire +1 more source
Transformers in HVDC Transmission
Power transformers are integral in the HVDC transmission systems and provide multiple functions. Correctly optimised transformers lower the cost for other equipment in HVDC schemes. This article describes the basics of HVDC and gives a view of where the HVDC development stands today.
Stoor, Matti, Canelhas, Andre
openaire +1 more source
DC protection coordination for multi‐terminal HB‐MMC‐based HVDC grids
Fast progress of High Voltage Direct Current (HVDC) technology has been considerable over the past decades. Emerging Modular Multilevel Converter (MMC) provides power systems with promising solutions to integrate large‐scale renewable energy sources, as ...
Seyed Hassan Ashrafi Niaki +5 more
doaj +1 more source
High-voltage direct current (HVDC) transmission systems are increasingly used for long-distance power transmission and the integration of renewable energy sources. In such systems, outdoor insulators are exposed to combined electrical stresses, including
Julian Hanusrichter, Frank Jenau
doaj +1 more source
HVDC System: a Need for Future Power Transmission [PDF]
The continuously increasing demand for electric power and the economic access to remote renewable energy sources such as off shore wind power or solar thermal generation in deserts have revived the interest in high voltage direct current HVDC multiterminal systems networks .
openaire +1 more source
Transient overvoltage on overhead metal return lines of ±500 kV MMC-HVDC grid
The ±500 kV half-bridge modular multilevel converter-high-voltage DC (MMC-HVDC) grid project with overhead transmission line is under construction in China at present.
Huiwen He +4 more
doaj +1 more source