Results 61 to 70 of about 6,910 (228)
Energy transmission by HVDC systems: theory and analytical simulations
reservedLa trasmissione di energia tramite sistema HVDC (High Voltage Direct Current) è una tecnologia utilizzata per il trasferimento efficiente di grandi quantità di energia elettrica su lunghe distanze.
NICHIFOREL, EMANUEL
core
Behaviour of HVDC Cables Under Variable Load Conditions: PD Detection and Recognition [PDF]
HVDC technology is widely used today in the field of energy transmission over long distances and with underground or submarine cable lines. The advantages of these applications lie in the absence of stability and transport capacity problems which ...
Romano P. +5 more
core +1 more source
Dynamic Behaviour of Bubbles in Oil Under Electrothermal Ageing
ABSTRACT During long‐term operation of converter transformers, the internal oil–pressboard insulation undergoes irreversible degradation. Partial discharge in the weakened insulation will cause the formation of a large number of bubbles in the insulating oil.
Hongbin Wu +7 more
wiley +1 more source
HVDC Transmission system model.
HVDC Transmission system model.
Qiaomei Wang (1710562) +4 more
core +1 more source
Quality Management System and Maturity Evaluation of Overseas Flexible HVDC Transmission Project
There are certain differences between the quality management of overseas flexible HVDC transmission project and domestic engineering quality management. In the management process, it is necessary to establish a correct quality management concept based on
Jiaqi CUI
doaj +1 more source
Effects of Conditional Changes on High-Voltage Direct Current Transmission Line Characteristic
The high-voltage direct current (HVDC) transmission system, which links the Gurun Substation of the National Electric Authority of Malaysia (Tenaga Nasional Berhad, TNB) with the Khlong Ngae Station of the Electricity Generating Authority of Thailand ...
Chaichan Pothisarn +6 more
doaj +1 more source
Development of ± 550 kV DC GIS Basin Insulator
ABSTRACT The basin insulator is a core component of the insulation system for ± 550 kV gas‐insulated switchgear (GIS). This paper, using a finite element method for multi‐physics simulations of electric–thermal coupling, determines a geometry suitable for the industrial production of ± 550 kV GIS basin insulators.
Shaohua Cao +9 more
wiley +1 more source
Grid-Forming Operation of the HVDC Tyrrhenian Link-East for Improved Frequency Transients
The paper examines the possibility of operating the VSC (Voltage Source Converter)-based HVDC (High Voltage Direct Current) Tyrrhenian Link-East with grid-forming capabil-ities.
Angelo L'Abbate +6 more
core +1 more source
This research paper addresses the issue of enhancing the operational availability of NPC three-level converter-based high-voltage direct current (HVDC) transport systems during alternating current (AC) grid fault conditions.
Ilyass El Myasse +3 more
doaj +1 more source
ABSTRACT Converter transformer vibration failures, primarily because of winding and core vibrations, severely impact the safe operation of high voltage direct current (HVDC) systems. These vibrations are influenced by voltage and current, and are transmitted through transformer oil and structural components to the tank. Current numerical models fail to
Peiyu Jiang, Fanghui Yin, Liming Wang