Results 181 to 190 of about 1,710 (215)
Some of the next articles are maybe not open access.
A novel protection scheme for HVDC transmission line
2011 International Conference on Advanced Power System Automation and Protection, 2011The formation of the transient capacitive current and its effects on the HVDC transmission line differential protection is analyzed based on the wave propagation principle in this paper. The magnitude of capacitive current in the transient process of DC line fault is directly proportional to the time difference of fault signal travelling to both ...
XiaoDong Zheng +6 more
openaire +1 more source
A protection system for long HVDC transmission lines
Proceedings of the Inaugural IEEE PES 2005 Conference and Exposition in Africa, 2006A recent review of the currently used HVDC line protection systems clearly indicated that these systems were not adequately equipped to protect HVDC schemes with extremely long HVDC transmission lines. Therefore, considering the increase in HVDC transmission line lengths projected for the future HVDC schemes, it is of vital importance that some type of
D. Naidoo, N.M. Ijumba
openaire +1 more source
EM Environmental Evaluation of HVDC Transmission Lines
The 2006 4th Asia-Pacific Conference on Environmental Electromagnetics, 2006Due to the high voltage operation of transmission lines, corona discharge phenomena are quite common around AC and DC transmission lines. A large amount of positive and/or negative ions are generated during the corona processes. The effects of corona space charge arising from HVDC transmission lines are much more significant than that in AC ...
Huiliang Zhao +3 more
openaire +1 more source
The fault location method for HVDC transmission line
2006 China International Conference on Electricity Distribution (CICED 2006), 2006The integrative fault location approach which combines the single terminal, dual terminals traveling wave location method and traditional fault location method has been brought forward. The new approach could fetch up the deficiency of the dual terminals traveling wave location method. The possible unsuccessful case of traveling wave fault location has
null Yongchang Zhai, null Haifeng Zhang
openaire +1 more source
Conductor surface voltage gradients on bipolar HVDC transmission lines
IEEE Transactions on Power Apparatus and Systems, 1976The method of successive images is used to obtain accurate values of maximum surface voltage gradients for practical HVdc transmission lines. The results are presented in the form of graphs of gradient factors as a function of the principal line parameters.
Morris, R. M., Maruvada, P. S.
openaire +2 more sources
Test Line Experience with HVDC Overhead Transmission
IEEE Transactions on Power Apparatus and Systems, 1970Tests were conducted on a high-voltage overhead direct-current test line. Values of radio interference and corona loss were established for certain conductor configurations and pole spacings. Relations between radio interference and corona loss and some weather variables were evaluated.
openaire +1 more source
The simulation study on line protection of HVDC transmission system
2017 2nd International Conference on Power and Renewable Energy (ICPRE), 2017This paper introduces the causes of line fault and expounds traveling wave protection and the criterion of protection action. Then establishes the simulation model of HVDC transmission system based on PSCAD/EMTDC, by which the line fault under different transition resistance and fault distance are simulated.
Huidong Guo +3 more
openaire +1 more source
Adaptive Reclosing Method for Flexible HVDC Transmission Lines
2020 4th International Conference on HVDC (HVDC), 2020With the development of HVDC transmission, half-bridge modular multilevel converter with hybrid HVDC circuit breakers becomes one of the mainstream configuration schemes in HVDC flexible system. However, the existing reclosing strategies have some defects, such as lack of selectivity and adoption of long time delay, due to the inability to determine ...
Mengxi Wang +2 more
openaire +1 more source
Integrated Wind Turbines and HVDC Power Transmission Lines
IEEE Transactions on Sustainable EnergyNasser Danapour S +2 more
exaly +2 more sources
A Novel Fault Location Method for HVDC Transmission Lines
2019 IEEE PES GTD Grand International Conference and Exposition Asia (GTD Asia), 2019Considering the frequency-dependent characteristics of line parameters, a novel fault location method for high voltage direct current (HVDC) transmission lines is proposed in this paper. It is of great significance to accurately establish transmission line model.
Liming Yang +5 more
openaire +1 more source

