A Modified Hybrid DC Circuit Breaker With Reduced Arc for Low Voltage DC Grids
The increasing demand for the development and utilization of renewable energy resources has lead to a growing interest in the development of LVDC systems.
C. N. Muhammed Ajmal +4 more
doaj +1 more source
DC fault isolation study of bidirectional dual active bridge DC/DC converter for DC transmission grid application [PDF]
Fast isolation and detection of DC faults is currently a limiting factor in high power DC transmission grid development. Recent research has shown that the role of DC/DC converters is becoming increasingly important in solving various DC grid challenges ...
Aboushady, Ahmed A. +2 more
core +2 more sources
A fast LVDC vacuum hybrid circuit breaker: Dielectric recovery and design consideration
Aiming at the fast protection requirements of electrical ships LVDC distribution system, this paper studies a topology of unidirectional vacuum hybrid circuit breaker.
Siqi Liu +4 more
doaj +1 more source
Fault Interruption Scheme for HVDC System Using SiC-MESFET and VCB Based Hybrid Circuit Breaker
As high voltage DC power system is gaining popularity, power electronic switching devices are becoming increasingly advanced to overcome problems of timely fault isolation.
Waheed A. Khan +6 more
doaj +1 more source
Impact of marine power system architectures on IFEP vessel availability and survivability [PDF]
In recent years integrated full electric propulsion (IFEP) has become a popular power system concept within the marine community, both for the naval and the commercial community.
Booth, C.D. +3 more
core +1 more source
System configuration, fault detection, location, isolation and restoration: a review on LVDC Microgrid protections [PDF]
Low voltage direct current (LVDC) distribution has gained the significant interest of research due to the advancements in power conversion technologies. However, the use of converters has given rise to several technical issues regarding their protections
Bououden +11 more
core +1 more source
Current Limiting Hybrid High Voltage DC Circuit Breaker With Reclosing Function Limiting
DC circuit breaker is the core equipment for the safe operation of DC transmission system. A current limiting hybrid HVDC circuit breaker topology with reclosing function is proposed in this paper.
Baoge Zhang +4 more
doaj +1 more source
Development and Application of a 10 kV Mechanical DC Circuit Breaker
A DC circuit breaker is piece of core equipment for DC grid construction and can achieve fast isolation of DC faults in the grid. In this paper, based on the fault characteristics and protection requirements of an AC/DC hybrid distribution network, the ...
Lu Qu +5 more
doaj +1 more source
Automated post-fault diagnosis of power system disturbances [PDF]
In order to automate the analysis of SCADA and digital fault recorder (DFR) data for a transmission network operator in the UK, the authors have developed an industrial strength multi-agent system entitled protection engineering diagnostic agents (PEDA).
Davidson, E.M., McArthur, S.D.J.
core +1 more source
The analysis and calculation of the short-circuit fault current in the DC grid is of great significance to the design and configuration of the converter station and DC circuit breaker parameters.
Haipeng Jia +5 more
doaj +1 more source