New Design of Hydrogenerator Poles.

RE&PQJ, 2023
HydrogeneratorThe excess of reactive power generated by power transmission lines is the reason for impermissible increase of voltage at the terminals of the length power transmission lines for consumers. One of the alternative decisions for this problem could become at the hydropower station hydrogenerators, specially designed or reconstructed for ...
openaire   +1 more source

A digital governor for hydrogenerators

IEEE Transactions on Energy Conversion, 1988
The authors describe the development and testing of a microcomputer-based digital governor for hydrogenerators. The digital governor was shown to approximate the control function of existing analog controllers. This task was performed as a first step to future work intended to utilize the versatility of microcomputers in effecting more sophisticated ...
L.D. Murphy, L. Wozniak, T.A. Whittemore
openaire   +1 more source

Experimental model of a hydrogenerator with static excitation

2011 IEEE EUROCON - International Conference on Computer as a Tool, 2011
In this paper is presented an experimental model for an hydro aggregate with synchronous generator having static excitation. The model was designed and achieved in the laboratory at reduced scale, of 12 kVA, using a VI — LabVIEW environment. With the help of this model there might be experimentally studied the dynamic conditions of the real hydro ...
Marius Biriescu   +6 more
openaire   +2 more sources

Asynchronous operation of hydrogenerator calculation verification by tests on old hydrogenerator in power plant

Proceedings of the 12th IEEE Mediterranean Electrotechnical Conference (IEEE Cat. No.04CH37521), 2004
The extended testing of hydrogenerator (rated 35 MVA) was made because the generators working age expired and it was going to be replaced with new one. This was the perfect opportunity to do some specific and not usual testing. The complicated testing plan was designed in order to enable recording as much relevant data as possible (electrical ...
Z. Zebic, Z. Maljkovic, M. Pavlica
openaire   +1 more source

Mechanical behavior of hydrogenerator endwindings

IEEE International Electric Machines and Drives Conference. IEMDC'99. Proceedings (Cat. No.99EX272), 2003
This paper presents experimental investigations on hydrogenerator endwinding vibrations and temperatures. In steady-state operation, links between machine load, winding mechanical characteristics, and temperature are discussed. Viscoelastic properties of coil composite sections are proved.
A. Jarosz   +4 more
openaire   +1 more source

Dynamics of Large Hydrogenerators

1996
Based on experimental data, this paper shows that the mathematical models of large hydrogenerators, used to preview the dynamic behavior at the design phase or as a predictive maintenance tool at the operation phase, must include the effects of the stiffness and damping forces of the oil film in the guide bearings.
G. C. Brito   +2 more
openaire   +1 more source

Thermographic evaluation of hydrogenerator losses

SPIE Proceedings, 2012
The calorimetric method has for a long time been applied for losses measurement and energy conversion efficiency determination in electrical machines. The number of temperature sensors necessary for its successful application in the field constitutes in one of the major drawbacks of the method.
Edson da Costa Bortoni   +1 more
openaire   +1 more source

Output Error Identification of Hydrogenerator Conduit Dynamics

IEEE Power Engineering Review, 1989
Two output error model reference adaptive identifiers are considered for estimating the parameters in a reduced-order gate position to pressure model for the hydrogenerator. Gradient and sensitivity function identifiers are discussed for hydroelectric applications, and connections are made between their structural differences and relative performance ...
M.A. Vogt, L. Wozniak, T.R. Whittemore
openaire   +1 more source

Hydrogenerator insulation maintenance practices

1983 EIC 6th Electrical/Electronical Insulation Conference, 1983
Reliable generation requires a comprehensive preventive maintenance program to locate defects and arrest deterioration on electrical generating equipment. This paper outlines one utility's preventive maintenance and investigative practices on hydro-generator insulation systems and describes experience on some of the major repairs and overhauls.
G. G. McCrae, G. Dang
openaire   +1 more source