Results 181 to 190 of about 1,926 (232)
The Complex World of Toothpaste Diversity, Meeting Patient Clinical Needs. An Umbrella Review
ABSTRACT Background Amidst numerous recent advancements in toothpaste formulations and active ingredients, some clinicians may believe all toothpastes are similar despite differences in their active ingredients and corresponding clinical application.
Jeanie Suvan, Crystal Marruganti
wiley +1 more source
ABSTRACT Objective This scoping review aimed to (1) map, analyse, interpret and synthesize data from clinical trials on topical alternatives used to prevent and/or reduce sensitivity caused by in‐office tooth bleaching; and (2) characterize the available evidence on their use for managing sensitivity.
Erik Vinícius Martins Jácome +3 more
wiley +1 more source
Some of the next articles are maybe not open access.
Related searches:
Related searches:
Thermoluminescence in hydroxyapatite
Medical Physics, 1979A thermoluminescent (TL) glow peak has been shown to exist at 80°C in synthetic hydroxyapatite, in amorphous calcium phosphate, and in deproteinated rat bone mineral. This TL glow peak is excited by a thermal pretreatment at elevated temperature, followed by exposure to ultraviolet (UV) light. When measured on a cylic TL‐readout UV‐exposure basis after
M R, Chapman, A G, Miller, T G, Stoebe
openaire +2 more sources
Science, 1973
The existence of a monoclinic phase of hydroxyapatite, Ca 5 (PO 4 ) 3 OH, has been confirmed, by single-crystal structure analysis (weighted "reliability" factor = 3.9 percent on |F| 2
J C, Elliott, P E, Mackie, R A, Young
openaire +2 more sources
The existence of a monoclinic phase of hydroxyapatite, Ca 5 (PO 4 ) 3 OH, has been confirmed, by single-crystal structure analysis (weighted "reliability" factor = 3.9 percent on |F| 2
J C, Elliott, P E, Mackie, R A, Young
openaire +2 more sources
Hydroxyapatite and Hydroxyapatite-Based Ceramics
Inorganic Materials, 2002Data are summarized on the synthesis of hydroxyapatite (HA) by wet-chemical processes, solid-state reactions, and hydrothermal treatment. The conditions for HA preparation via precipitation from solutions of calcium chloride, dibasic ammonium phosphate, and aqueous ammonia are discussed at length.
V. P. Orlovskii +2 more
openaire +1 more source
Comparison of hydroxyapatite and hydroxyapatite tricalcium-phosphate coatings
The Journal of Arthroplasty, 2002This study compared the effects of hydroxyapatite (HA) coating and biphasic HA/tricalcium-phosphate (HA/TCP) coating on the osseointegration of grit-blasted titanium-alloy implants. Each coated implant was compared with uncoated grit-blasted implants as well.
Tetsuya, Jinno +2 more
openaire +2 more sources
Nanofiber generation of hydroxyapatite and fluor‐hydroxyapatite bioceramics
Journal of Biomedical Materials Research Part B: Applied Biomaterials, 2005AbstractIn this study, we produced hydroxyapatite (HA) and fluor‐hydroxyapatite (FHA) bioceramics as a novel geometrical form, the nanoscale fiber, for the biomedical applications. Based on the sol‐gel precursors of the apatites, an electrospinning technique was introduced to generate nanoscale fibers.
Hae-Won, Kim, Hyoun-Ee, Kim
openaire +2 more sources
Adsorption of Catalase on Hydroxyapatite
Journal of Colloid and Interface Science, 1998The adsorption of catalase on calcium hydroxyapatite is reported in this study. In all the solutions investigated, catalase adsorption takes place under conditions where the adsorbent and the adorbate are both negatively charged and is accompanied by the release of phosphate ions. This suggests that electrostatic attraction does not play a leading role
Barroug, A. +3 more
openaire +3 more sources
Orthopedics, 1994
ABSTRACTA series of investigations over the past several years has evaluated a number of implant materials with and without plasma-sprayed hydroxyapatite (HA) coatings for use in load-bearing implant applications. HA-coated implants have exhibited greater interface shear attachment characteristics when compared to uncoated implants; these results have ...
openaire +2 more sources
ABSTRACTA series of investigations over the past several years has evaluated a number of implant materials with and without plasma-sprayed hydroxyapatite (HA) coatings for use in load-bearing implant applications. HA-coated implants have exhibited greater interface shear attachment characteristics when compared to uncoated implants; these results have ...
openaire +2 more sources
Clinical Orthopaedics and Related Research, 1988
Significant interest for orthopedic surgical applications of hydroxyapatite compounds is based on a number of reasons including the elemental chemistry of the primarily calcium and phosphate ion substances, the controllability of the crystalline and physical structures to provide a wide range of in vivo interactions, the existing literature on ...
openaire +2 more sources
Significant interest for orthopedic surgical applications of hydroxyapatite compounds is based on a number of reasons including the elemental chemistry of the primarily calcium and phosphate ion substances, the controllability of the crystalline and physical structures to provide a wide range of in vivo interactions, the existing literature on ...
openaire +2 more sources

