Results 111 to 120 of about 180,532 (304)
Plasma‐sequence‐engineered ALD (PSE‐ALD), based on sequential NH3 and N2 plasma pulses, enables ultrathin, dense SiNx films. ToF‐MS analysis confirms ligand removal via HCl evolution, while increased film density indicates network densification. The resulting SiNx coating provides robust protection of graphite under H2 plasma exposure.
Hye‐Young Kim +7 more
wiley +1 more source
Bioresorbable electrochemical sensors face instability in biofluids. Although alloys can mitigate rapid in vivo dissolution, Mo–W remains underexplored for sensing. This work engineers Mo–W films with a nanocrystalline oxide coating, improving stability and enabling reliable oxygen and pH sensing for up to 10 days, highlighting their potential for ...
C. Fernandes +4 more
wiley +1 more source
Elemental analysis of atherosclerotic plaque by ICP-MS and LA-ICP-MS
AT_PUBLICATION
Toczyłowska, Beata +8 more
openaire +1 more source
The new Super-Kamiokande-Gadolinium (SK-Gd) project is an upgrade of the Super-Kamiokande (SK) detector. In the SK-Gd project, 0.2\% Gd$_2$(SO$_4$)$_3$ is loaded into the 50 kton water tank of the SK.
Ikeda, M. +3 more
core +1 more source
Transducers convert physical signals into electrical and optical representations, yet each mechanism is bounded by intrinsic trade‐offs across bandwidth, sensitivity, speed, and energy. This review maps transduction mechanisms across physical scale and frequency, showing how heterogeneous integration and multiphysics co‐design transform isolated ...
Aolei Xu +8 more
wiley +1 more source
Risk of overestimation of urinary cadmium concentrations: interference from molybdenum
We show here that the selection of analytical method is critical when measuring low levels of cadmium in human urine. Cadmium is today usually analyzed by Inductively Coupled Plasma Mass Spectrometry (ICP-MS), which has a higher sensitivity than Atomic ...
Cañas A.I. +3 more
doaj +1 more source
An inter-comparison exercise on the application of ICP-MS techniques for measurement of long-lived radionuclides [PDF]
Inductively coupled plasma (ICP) spectrometry techniques are widely used in the fields related to environmental monitoring, nuclear waste disposal and management, radioecology and tracer studies, as well as nuclear forensics and nuclear emergency ...
Engström, Emma +8 more
core
Degradation Mechanisms in PEM Water Electrolysis: Diagnosis and Impact
This review provides an analysis of degradation mechanisms in proton electrolyte membrane water electrolyzers (PEMWE), focusing on all key components. It discusses diagnostic and measurement techniques for evaluating degradation, less‐studied mechanisms, and an expert survey.
Annik Bernhardt +11 more
wiley +1 more source
Visual teach‐and‐repeat (VTR) navigation allows robots to learn and follow routes without building a full metric map. We show that navigation accuracy for VTR can be improved by integrating a topological map with error‐drift correction based on stereo vision.
Fuhai Ling, Ze Huang, Tony J. Prescott
wiley +1 more source

