Results 11 to 20 of about 4,460,967 (133)
Pediatric phantom library constructed from ICRP mesh-type reference computational phantoms (MRCPs)
International Commission on Radiological Protection (ICRP) recently developed the adult and pediatric mesh-type reference computational phantoms (MRCPs) in high-quality/fidelity mesh format, featuring high deformability into various body sizes and poses.
Suhyeon Kim +12 more
doaj +5 more sources
New thyroid models for ICRP pediatric mesh-type reference computational phantoms
As part of the ICRP Task Group 103 project, we developed ten thyroid models for the pediatric mesh-type reference computational phantoms (MRCPs). The thyroid is not only a radiosensitive target organ needed for effective dose calculation but an important
Yeon Soo Yeom +11 more
doaj +4 more sources
Recently, the International Commission on Radiological Protection (ICRP) has developed the Mesh-type Reference Computational Phantoms (MRCPs) for adult male and female to overcome the limitations of the current Voxel-type Reference Computational Phantoms
Yeon Soo Yeom +7 more
doaj +4 more sources
The International Commission on Radiological Protection (ICRP) recently released the pediatric mesh-type reference computational phantoms (MRCPs) through ICRP Publication 156 to overcome the limitations of the pediatric voxel-type reference computational
Chansoo Choi +4 more
doaj +4 more sources
The present study provides updated S values (rT ← thyroid) for 30 radiosensitive organs/tissues for pediatric patients undergoing radioiodine therapy with iodine-131, utilizing the pediatric mesh-type reference computational phantoms (MRCPs) very ...
Chansoo Choi +3 more
doaj +4 more sources
The International Commission on Radiological Protection (ICRP) Publication 116 was released to provide a comprehensive dataset of the dose coefficients (DCs) for external exposures produced with the adult reference voxel phantoms of ICRP Publication 110.
Bangho Shin +5 more
doaj +4 more sources
Developing the Adult Male ICRP Phantom and Evaluation the Absorbed Dose Received By Critical Organs in Head and Neck Region during the Radiotherapy of Eye Cancer [PDF]
Introduction Accurate estimation of the absorbed dose in radiosensitive organs, located away from the target volume during radiotherapy, is one of the main reasons for the development of reference phantoms.
Alireza Vejdani-Noghreiyan +1 more
doaj +2 more sources
Specific Absorbed Fractions for Spontaneous Fission Neutron Emitters in the ICRP Reference Pediatric Voxel Phantom Series [PDF]
Abstract Specific absorbed fractions (SAFs) are key components in the workflow of internal exposure assessment following the intake of a radionuclide, allowing quick conversion of particle energy released in a source region to the expected absorbed dose in target regions throughout the body. For data completeness,
Griffin, Keith +5 more
openaire +5 more sources
ICRP Publication 116 on 'Conversion coefficients for radiological protection quantities for external radiation exposures', provides fluence-to-dose conversion coefficients for organ-absorbed doses and effective dose for various types of external exposures (ICRP 2010 ICRP Publication 116).
Nina, Petoussi-Henss +9 more
core +4 more sources
In diagnostic nuclear medicine, mean absorbed doses to patients' organs and effective doses are published for standard stylised anatomic models. To provide more realistic and detailed geometries of the human morphology, the International Commission on Radiological Protection (ICRP) has recently adopted male and female voxel phantoms to represent the ...
Hadid, L., Gardumi, A., Desbrée, A.
openaire +3 more sources