Results 31 to 40 of about 4,460,967 (133)
Dosimetric modeling of radiation transport in skeletal bone tissues using computational phantoms provides the doses of internal exposure to active marrow.
E. A. Shishkina +2 more
doaj +1 more source
Dose coefficients for ICRP reference pediatric phantoms exposed to idealised external gamma fields [PDF]
Abstract Organ and effective dose coefficients have been calculated for the International Commission on Radiological Protection (ICRP) reference pediatric phantoms externally exposed to mono-energetic photon radiation (x- and gamma-rays) from 0.01 to 20 MeV. Calculations used Monte Carlo radiation transport techniques.
Lienard A, Chang +4 more
openaire +2 more sources
The effective dose is an important tool in the radiation protection community because it represents the health risk associated with different procedures involving ionizing radiation, and therefore it allows comparing them. Therefore, accurate determination of the effective dose for nuclear medicine procedures is important.
A. Sadre Momtaz, F. Safarnejad
openaire +2 more sources
In Molecular Radiation Therapy, the estimation of energy absorbed within tissue is critical for the assessment of the e cacy of radiopharmaceuticals. Computational phantoms are a valuable tool to estimate radiation dose and to ensure that radiation dose ...
Samuel Montgomery Lilli (20168163)
core
Monte Carlo simulation of photon breast radiotherapy of the pregnant patient beam characteristics [PDF]
This paper aims to describe the photon beam characteristics in terms of energy and angular distribution during breast megavoltage photon radiotherapy of pregnant patients. Photon beam characteristics are investigated at treatment volume (breast)
Faj Dario +6 more
doaj +1 more source
An efficient radiosynthesis of fluorine‐18 labeled gluconic acid ([18F]FGA) was developed using two readily available materials, 2‐deoxy‐2‐[18F]fluoro‐D‐glucose ([18F]FDG) and glucose oxidase. [18F]FGA is highly specific for bacterial gluconate metabolism mediated by gluconate permease (GntP) and gluconate kinase (GntK), with rapid clearance, low off ...
Sang Hee Lee +7 more
wiley +2 more sources
In vivo internal dosimetry can use a whole-body counter (WBC) to estimate radionuclides' incorporated activity (Bq) in internally contaminated individuals. The WBC must be calibrated to convert the count rate from the detector into activity incorporated
Hirys Sales, Ester Andrade, Bruno Mendes
doaj +1 more source
In a previous study, a set of polygon-mesh (PM)-based skin models including a 50-μm-thick radiosensitive target layer were constructed and used to calculate skin dose coefficients (DCs) for idealized external beams of electrons.
Yeon Soo Yeom +6 more
doaj +1 more source
Abstract Recently, the Task Group 103 of the International Commission on Radiological Protection (ICRP) has developed new mesh-type reference computational phantoms (MRCPs) for adult male and female. When compared to the current voxel-type reference computational phantoms in ICRP Publication 110, the MRCPs have several advantages ...
Hanjin Lee +9 more
openaire +4 more sources
Computational phantoms, ICRP/ICRU, and further developments
Phantoms simulating the human body play a central role in radiation dosimetry. The first computational body phantoms were based upon mathematical expressions describing idealised body organs. With the advent of more powerful computers in the 1980s, voxel
C.H. Kim +5 more
core +1 more source

