Results 171 to 180 of about 6,331 (209)
Some of the next articles are maybe not open access.
New control functions for IEC 61850
2017 IEEE 15th International Conference on Industrial Informatics (INDIN), 2017The advantages of standardizing communications for implementing a Smart Grid depends on the adaptability and general ongoing extension of communication standards in order to include new innovative functions. The BMWi-funded project Green Access demonstrates which possible new control functions could be adopted for extending the communication standard ...
Julia Masurkewitz-Möller +3 more
openaire +1 more source
Substation automation system using IEC 61850
2011 5th International Power Engineering and Optimization Conference, 2011Substation has a critical role in power network because it is a subsidiary station of an electricity generation, transmission and distribution system where voltage is transformed from high to low or the reverse with power transformers. All devices in substation are controlled, protected and monitored by substation automation system (SAS) that collects ...
S. Roostaee +2 more
openaire +1 more source
IEC 61850 impact on substation design
2008 IEEE/PES Transmission and Distribution Conference and Exposition, 2008IEC 61850 communication networks and systems for utility automation is a standard for communications that creates an environment that will allow dramatic changes in the design and operation of substations. The paper describes the different components of such systems and the distribution of functions between the devices included in it.
M. C. Janssen, A. Apostolov
openaire +1 more source
The PMU interface using IEC 61850
2013 International Conference on ICT Convergence (ICTC), 2013As industry develops, the complexity of power networks will increase, which will place heavier demands on their reliable management. To increase the reliability of power networks, new technologies related to the operation of smart grids and micro grids are currently under development, and various intelligent devices are applied to control and monitor ...
null Jae-Duck Lee +3 more
openaire +1 more source
Engineering perspectives on IEC 61850
IEEE Power and Energy Magazine, 2007The aim of this paper is to discuss the benefits as well as the necessary changes linked to this substation automation communication technology. More specifically, this paper addresses the evolutions to be done during system engineering in order to properly use the capabilities of the IEC 61850 toolbox.
openaire +1 more source
Industry Viewpoints on IEC 61850
Adopting IEC 61850 promises utilities the ability to design and build protection, control, and automation schemes more quickly and efficiently, and provide easy access to data to drive solutions to operate substations and the overall power system better.Ramesh Koripella +3 more
openaire +2 more sources
IEC 61850 Based Protection Systems
2019The chapter includes protection power systems based on the IEC 61850 protocol for data communication systems between substations. The IEC 61850 is adequate for real time communication between IED based on GOOSE messages. The chapter includes the case study from the Romanian power systems: implementation of protection and remote control system in ...
Marian Gaiceanu, Iulian Nicusor Arama
openaire +1 more source
IEC 61850 communication based distance protection
Proceedings of the 2014 15th International Scientific Conference on Electric Power Engineering (EPE), 2014IEC 61850 is the standard for communication substation which determines new applications of protection based on peer-to-peer communications between multifunctional protection devices (IEDs). The GOOSE messages (Generic Object Oriented Substation Event) can be used to replace the hard wired control signals exchanged between IEDs for interlocking and ...
Kinan Wannous, Petr Toman
openaire +1 more source
2016
Before discussing operational applications over utility telecom networks, a brief introduction is necessary on IEC 61850 standards. The initial objective of this standardization effort was to define vendor-independent data exchange architecture for the electrical substation automation system allowing interoperability of devices from different vendors ...
openaire +1 more source
Before discussing operational applications over utility telecom networks, a brief introduction is necessary on IEC 61850 standards. The initial objective of this standardization effort was to define vendor-independent data exchange architecture for the electrical substation automation system allowing interoperability of devices from different vendors ...
openaire +1 more source
Applying XML technology to IEC-61850
2006 China International Conference on Electricity Distribution (CICED 2006), 2006The paper discusses how to apply XML technology to create, parse and validate a SCL file in the development of system configuration tool for IEC-61850. It introduces DOM, the key technology of development. The paper discusses four applications cases in System Configurator for IEC-61850. (5 pages)
null Changwu Ma +5 more
openaire +1 more source

