IEC 61850 substation experiences
11th IET International Conference on Developments in Power Systems Protection (DPSP 2012), 2012The advent of IEC61850 Standard has ushered a new age for substation automation. This standard has gained a very strong footing in Europe and its application is spreading across the world. In USA the progress towards IEC61850 implementation is relatively slower. IEC61850 holds great promises for substation automation and protection.
M. Childers, M. Borrielli
openaire +1 more source
Rejuvenation of the IEC 61850 protocol stack for MMS
2016 IEEE International Conference on Smart Grid Communications (SmartGridComm), 2016One of the most important Smart Grid Control Protocols is MMS over IEC 61850, which is predicted a great future after its extension for usage over Wide Area Networks and its generalization for other Smart Grid and industrial applications. Nevertheless the protocol stack of IEC 61850, which is used for MMS, originated from the 80s of the last century ...
Christoph Ruland +2 more
openaire +1 more source
2019 1st Global Power, Energy and Communication Conference (GPECOM), 2019
Part of the pre-commissioning test in a conventional substation is wires checking. This is usually done by verifying connectivity and measuring voltage using the trusty multimeter. In a substation where fiber optic and data cables are used instead of copper wires, new tools have to be utilized.
Andrea Bonetti +2 more
openaire +1 more source
Part of the pre-commissioning test in a conventional substation is wires checking. This is usually done by verifying connectivity and measuring voltage using the trusty multimeter. In a substation where fiber optic and data cables are used instead of copper wires, new tools have to be utilized.
Andrea Bonetti +2 more
openaire +1 more source
IEC-61850 GOOSE traffic modeling and generation
2017 IEEE Global Conference on Signal and Information Processing (GlobalSIP), 2017The IEC-61850 standard for substation communication and automation presented a reliable alternative to legacy communication networks. IEC-61850 defined more than one type of messages, of which the Generic Object Oriented Substation Event (GOOSE) messaging was structured to handle control and commands with strict delay and reliability requirements. This
Omar Hegazi +3 more
openaire +1 more source
Harmonization of the CIM and IEC 61850
2011 IEEE/PES Power Systems Conference and Exposition, 2011Applications of the IEC 61970 and IEC 61968 Common Information Model (CIM) have been expanding from its traditional usage in power system modeling and data exchange into the role of a standardized semantic model for the Smart Grid. The NIST Smart Grid Interoperability Road Map has identified the need for a semantically consistent framework on which to ...
openaire +1 more source
Evaluating Cryptographic Algorithms in IEC 61850 Networks
2019 10th International Conference on Networks of the Future (NoF), 2019We evaluate in this paper several cryptographic algorithms applied to the GOOSE protocol in IEC 61850 communication networks for electric power substations. International Electrotechnical Commission (IEC) in its standards suggests to use RSA algorithm for digital signature of GOOSE messages and at the same time defines a maximum communication latency ...
Rafael B. Scarselli +2 more
openaire +1 more source
Bringing IEC 61850 and Smart Grid together
2011 2nd IEEE PES International Conference and Exhibition on Innovative Smart Grid Technologies, 2011In a world where Smart Grid is the hype, a crucial prerequisite for true “smart” transmission and distribution networks is currently missing; open standards-based communications must be available for the entire “monitoring, control and protection” chain.
M. C. Janssen +2 more
openaire +1 more source
Digital Substations with the IEC 61850 Standard
2021The IEC 61850 protocols for intelligent electronic devices (IEDs) are becoming popular in various applications of power systems, such as protection, control, monitoring in real-time operation, and integration of modern devices like IEDs, analog merging units and Ethernet networks.
Majid Jamil +3 more
openaire +1 more source
Utilizing possibilities of IEC 61850 and GOOSE
IET Conference Publications, 2009This document describes the utilization of some new features offered by IEC 61850, Communication Networks and Systems in Substations. In particular, the paper looks at how horizontal communication, commonly known as GOOSE communication, between protection and control devices can be used to improve the reliability and performance of the system.
A. Hakala-Ranta, O. Rintamaki, J. Starck
openaire +1 more source
Industry Viewpoints on IEC 61850
Adopting IEC 61850 promises utilities the ability to design and build protection, control, and automation schemes more quickly and efficiently, and provide easy access to data to drive solutions to operate substations and the overall power system better.Ramesh Koripella +3 more
openaire +2 more sources