Results 81 to 90 of about 75,636 (164)

Determinación de patrones de descargas superficiales y de efecto corona en aisladores poliméricos de 13.8 kV hasta 22 kV [PDF]

open access: yes
Este documento describe el comportamiento de los aislantes poliméricos al aplicar una cantidad controlada de voltaje, junto con su definición. Se han realizado pruebas de campo aplicando el voltaje necesario para las cuales se han creado.
Sanchez Pulla, Luis Alberto   +1 more
core   +2 more sources

GIS中局部放电特高频信号与放电严重程度的关联分析

open access: yesGaoya dianqi, 2014
局部放电激发的特高频信号大小与放电严重程度紧密相关,笔者利用220 kV GIS设备,采用特高频检测法和IEC 60270—2000检测法同时对多种典型局部放电源进行试验。通过分析特高频信号的时域峰峰幅值与局部放电量之间的关联,发现不同类型局部放电源所激发的特高频信号峰峰值与视在放电量的对应关系存在显著差异。针对不同局部放电源特有的物理结构,通过对放电机理的对比分析,给出了不同缺陷激发的特高频信号峰峰值与视在放电量关系不一致原因的定性解释。
丁登伟, 高文胜, 刘卫东
doaj  

基于随机决策森林的高压电缆局部放电模式识别

open access: yesGaoya dianqi, 2022
不同类型的高压电缆局部放电(简称局放)模式识别是该领域的难题。部分电缆局放类型之间相似度较大,识别困难。针对该问题,文中提出了一种基于随机决策森林(RF)的高压电缆局放模式识别方法。首先,制作了5种高压电缆人工缺陷,结合IEC 60270—2015系统和高频电流互感器(HFCT)进行实验,获取局放数据,并进行局放特征提取。其次,介绍了随机森林算法的原理和基于随机森林的高压电缆局放模式识别流程。最后,基于实验所得数据开展了局放模式识别方法有效性验证,确定了随机森林每个节点处特征子集中特征个数、节点分裂规则、
刘文浩   +6 more
doaj  

Guided Ultrasound Horn-Enhanced Fiber Bragg Grating Sensor for Partial Discharge Detection in HV Equipment

open access: yesEnergies
Insulation deterioration is the leading cause of premature failures in high-voltage (HV) power equipment, with partial discharge (PD) serving as a key indicator of insulation health.
Krishanlal Adhikari   +4 more
doaj   +1 more source

油纸绝缘气隙模型局部放电特性试验研究

open access: yesGaoya dianqi, 2012
为了研究直流输电系统中换流变压器油纸绝缘的局部放电特性,设计构造了典型的油纸局部放电模型———气隙放电模型。针对同一模型分别施以交流电压、直流电压以及冲击衰减振荡电压,采用IEC 60270-2000推荐的脉冲电流法分别检测与分析该模型局部放电的不同特征参数。对比研究了在交流、直流及振荡冲击电压下油纸绝缘气隙放电模型的局部放电脉冲特征参量包括局部放电起始电压、熄灭电压、放电波形、放电水平、放电重复率等,对实现换流变压器的局部放电在线监测与绝缘状态综合评估有一定的指导意义。
徐春社   +3 more
doaj  

Graph-Based Framework with Waveform-Informed Connectivity for Multi-Label Partial Discharge Source-Type Classification

open access: yesSensors
Partial discharge (PD) source-type classification is essential for condition-based maintenance of high-voltage apparatus. Existing approaches based on grid discretizations of phase-resolved partial discharge (PRPD) patterns suffer from performance ...
Leandro José Duarte   +6 more
doaj   +1 more source

Partial Discharge Behavior of Natural Origin Gases Depending on Gas Pressure and Electric Field Homogeneity

open access: yesEnergies
Gas-insulated switchgear (GIS) offers multiple advantages compared to air-insulated switchgear (AIS); primarily, due to its more compact design and reduced maintenance requirements. In recent years, environmentally friendly replacement gases for SF6 have
Niclas Dölzer   +2 more
doaj   +1 more source

Experimental Analysis of Electrical Degradation in Eco-Friendly Insulating Oil Using a Scaled-Down Transformer Internal Structure

open access: yesIEEE Access
This study comparatively examines the electrical degradation characteristics of MIDEL 7131, a synthetic ester-based eco-friendly insulating oil, against conventional mineral oil through laboratory-scale experiments.
Keon-Hee Park   +3 more
doaj   +1 more source

Precision Calibration System for Partial Discharge Calibrators

open access: yes, 2019
Partial discharge calibrators need to be periodically calibrated traceable to national standards. VTT MIKES, the National Metrology Institute (NMI) of Finland, has official expertise to calibrate the apparent charge of PD calibrators from 1 pC to 100 nC ...
Hällström, Jari; id_orcid   +3 more
core   +1 more source

Partial Discharge Severity Classification for Transformer Condition Monitoring Using Feature Engineering, PCA, and ANN

open access: yesMachines
Partial discharge (PD) is a key indicator of insulation degradation in high-voltage transformers and can provide early warning of incipient failure. Although artificial neural networks (ANNs) have been applied to PD classification, their performance may ...
Lucas Thobejane, Bonginkosi A. Thango
doaj   +1 more source