Results 61 to 70 of about 75,636 (164)

局放测量新标准IEC 60270的特点及其对局放测量工作的影响

open access: yesGaoya dianqi, 2001
局部放电测量的新标准IEC 6 0 2 70 /FDIS[2 0 0 0 ]已于2 0 0 0年 9月公布 ,该标准以IEC 6 0 0 6 0 - 2 [1994]为依据 ,为局放测量构筑了完整的质量保证体系 :它以量值溯源为核心 ,以保证测量结果的准确性、不同仪器和不同测量方法的可比性和一致性 ;它把数字式局放测试仪摆在与模拟式局放测试仪同等重要的地位 ,并为数字式局放测试仪规定了一些附加试验项目。本文讨论新标准的特点及其对今后局放测量工作的影响。
史志侠
doaj  

Partial discharge in switchgear elements [PDF]

open access: yes, 2011
V diplomskem delu je opisan pojav delnih praznitev. Delne praznitve so lokalizirane električne praznitve naboja, ki ne povzročijo preboja dielektrika med dvema prevodnikoma. Opisano je več vrst in vzrokov za pojav delnih praznitev.
Milin, Matija
core  

Insulation Fault Mechanism of 750 kV GIS Equipment Based on COMSOL Multiphysics Simulation Analysis

open access: yesJournal of Electrical and Computer Engineering, Volume 2025, Issue 1, 2025.
Gas‐insulated switchgear (GIS) is pivotal in high‐voltage transmission systems owing to its compact design, high reliability, and superior dielectric strength, facilitated by sulphur hexafluoride (SF6). However, metallic contaminants, introduced during manufacturing or operation, pose a substantial threat to the insulation integrity.
Liqing Dai, Tiesheng Xu, Manuela Minetti
wiley   +1 more source

局部放电校准仪的研究与设计

open access: yesGaoya dianqi, 2009
介绍了局部放电校准仪的设计原理,建立了局部放电校准仪的电路模型。通过对模型进行分析、计算,得出校准仪的输出电量与电阻分压比成正比。改变分压比就可以实现不同的输出电量。利用此校准仪进行测量实验,结果表明:其输出的实际电荷量满足IEC 60270标准中规定的指标。
王万岗   +4 more
doaj  

Enhanced complete ensemble EMD with superior noise handling capabilities: A robust signal decomposition method for power systems analysis

open access: yesEngineering Reports, Volume 6, Issue 11, November 2024.
Decomposition of the artificial signal by (A) EMD, (B) EEMD, (C) CEEMDAN producing 8 IMFs plus a residual, (D) impCEEMDAN producing 7 IMFs plus a residual, (E) ECEEMDAN producing 3 IMFs plus a residual and (E) expected decomposition with 3 IMFs plus a residual signal.
Manuel Soto Calvo, Han Soo Lee
wiley   +1 more source

Calibration Proposal for UHF Partial Discharge Measurements at Power Transformers

open access: yesEnergies, 2019
The continuous, non-intermitted service of electrical grids relies on the reliability of their assets, e.g., power transformers. Local insulation defects can result in serve failures such as breakdowns with severe subsequent costs. The prevention of such
Martin Siegel   +10 more
doaj   +1 more source

Architecture for automatically generating an efficient IEC 61850-based communications platform for rapid-prototyping of protection schemes [PDF]

open access: yes, 2011
Although offering many benefits, using IEC 61850 in the course of research and development of new protection schemes can be costly and time - consuming.
Burt, Graeme   +2 more
core   +3 more sources

Important election message : you're ready [PDF]

open access: yes, 1994
462.B.2.3(26).pdf created from the media publications in the SA Election material Collection MS 462, held in the Manuscripts Section of the Stellenbosch Library and Information Service.Important election message : you're ready. 1994.

core  

AC ripple on DC voltage: Experimental and theoretical investigation of the impact on accelerated ageing in electrical insulation

open access: yesHigh Voltage, Volume 9, Issue 4, Page 902-910, August 2024.
Abstract With the increasing penetration of DC systems into the high voltage and medium voltage power industry, DC voltage is becoming common for distribution/transmission and to supply different typologies of loads. The allowable extent of AC ripple superimposed to DC, and its effect on insulation ageing, is a long‐term discussed topic.
Giovanni Gardan, Gian Carlo Montanari
wiley   +1 more source

Experimental qualification and sensitivity study of antipodal patch antenna structures for orientation independent detection of partial discharges

open access: yesHigh Voltage, Volume 9, Issue 3, Page 674-684, June 2024.
Abstract Partial discharge diagnosis is an important part of monitoring and diagnosing components of the power transmission system. Four different patch antenna structures for the detection of partial discharges are investigated. These patch antennas, which are realisable in a variety of geometric structures, are already the subject of research.
Kerstin Friebe, Frank Jenau
wiley   +1 more source

Home - About - Disclaimer - Privacy