Machine Learning for Early Transformer Insulation Defect Risk Ranking
Early identification of transformer insulation defects during IEC 60270 induced-voltage acceptance testing could enable high-risk units to be prioritized before the guaranteed test voltage is reached.
Lucas Thobejane, Bonginkosi A. Thango
doaj +1 more source
Belangrike verkiesingsinligting : Ons sal jou reg om te stem beskerm [PDF]
462.B.2.3(8).pdf created from the media publications in the SA Election material Collection MS 462, held in the Manuscripts Section of the Stellenbosch Library and Information Service.Belangrike verkiesingsinligting : Ons sal jou reg om te stem beskerm ...
core +2 more sources
ABSTRACT This paper focuses on the energisation of high voltage DC (HVDC) and medium voltage DC (MVDC) insulation systems, referring mainly to cables for both theoretical development and validation testing. Cable system energisation can be frequent during its lifetime, and it can possibly be affected by partial discharges (PD), because of manufacturing,
Gian Carlo Montanari +4 more
wiley +1 more source
Power transformer partial discharge signal measurement using Radio Frequency method has advantages over IEC 60270 ‘apparent charge’ measurement method for online monitoring due to greater immunity against external interference.
Keyvan Firuzi +4 more
doaj +1 more source
Data sample from Israel Electric Corporation (IEC)
<p>The dataset contains logs from IT and OT systems collected from a testbed setup of the IEC.<br> The content is specifically related to:</p> <p>·CCTV and PTZ cameras.</p> <p>·Intrusion detection ...
IEC (7307195), IEC
core +1 more source
ABSTRACT Partial discharge (PD) is the indicator of the insulation defect in cables. However, the pulse current method, which is widely adopted in land cables, cannot obtain PD signals of high‐voltage direct current (HVDC) submarine cables due to attenuation and installation position.
Hang Wang +7 more
wiley +1 more source
Metal particles and bubbles are two typical impurities in transformer oil that can cause partial discharge (PD) and even electric breakdown. The PD characteristics are closely related to the motions of these impurities in flowing transformer oil. In this
Yongze Zhang +3 more
doaj +1 more source
ABSTRACT The air gap at the interface inside the cable terminations for high‐speed trains and the partial discharge caused by it are two important factors affecting the insulating performance. The development of air gap and partial discharge will eventually lead to breakdown faults.
Dongli Xin +7 more
wiley +1 more source
ABSTRACT Electrical insulation faults produce partial discharges (PD), which can be analysed to identify specific types of defects. PD clustering is a widely used method to identify PD sources, although its success depends largely on the feature maps used.
Jannery Rivas +4 more
wiley +1 more source
Abstract The interturn paper insulation of oil‐immersed power transformer windings, under the combined influence of electric fields, moisture, and conductor heating, will produce bubbles, which pose a significant threat to the insulation system. However, there is limited research on the characteristics of bubble evolution in oil–paper insulation under ...
Chaojie Yang +5 more
wiley +1 more source