Results 41 to 50 of about 75,636 (164)

The effects of drying time during manufacturing process on partial discharge of 83.3 mva 275/160 kv power transformer

open access: yesMATEC Web of Conferences, 2018
Power transformer (PT), essential equipment in electrical power system proceeds complicated manufacturing process to meet high standard design. During manufacturing process of PT, the drying stage is of importance to remove excessive moisture contaminant
Siswanto   +3 more
doaj   +1 more source

An open platform for rapid-prototyping protection and control schemes with IEC 61850 [PDF]

open access: yes, 2013
Communications is becoming increasingly important to the operation of protection and control schemes. Although offering many benefits, using standards-based communications, particularly IEC 61850, in the course of the research and development of novel ...
Coffele, Federico   +3 more
core   +4 more sources

Analysing the Impact of Frequency Bands on Partial Discharge Measurement Outcomes in Generators Through Model‐Based Approach

open access: yesHigh Voltage, Volume 11, Issue 2, Page 351-359, April 2026.
ABSTRACT The electromagnetic wave produced by a partial discharge (PD) covers a broad range of frequencies, from a few kHz to several 100 MHz. Because of the nonlinear response of the stator winding, each frequency component of the PD pulse experiences different levels of attenuation as it travels through the winding structure. Consequently, the choice
Arash Abyaz   +2 more
wiley   +1 more source

Study on Miniaturized UHF Antennas for Partial Discharge Detection in High-Voltage Electrical Equipment

open access: yesSensors, 2015
Detecting partial discharge (PD) is an effective way to evaluate the condition of high-voltage electrical equipment insulation. The UHF detection method has attracted attention due to its high sensitivity, strong interference resistance, and ability to ...
Jingcun Liu   +3 more
doaj   +1 more source

Application of the Chaotic System–Based Error Trace Diagrams for Partial Discharge Feature Extraction

open access: yesIET Science, Measurement &Technology, Volume 20, Issue 1, January/December 2026.
This study uses chaotic synchronisation and fractal analysis of acoustic partial discharge signals in 25‐kV cable joints. Extracted 3D error trace features combined with a neural network enable accurate, noise‐robust defect recognition, effectively distinguishing different cable joint defect types with high reliability and ease of implementation ...
Feng‐Chang Gu, Sen‐Fu Chan
wiley   +1 more source

Electrical apparatus for explosive gas atmospheres, Part 0: General introduction [PDF]

open access: yes, 1971
ERAF: 48409This Recommendation has been prepared by IEC Technical Committee No. 31, Electrical Apparatus for Explosive Atmospheres; It forms one of a series of publications dealing with electrical apparatus for use in explosive gas atmospheres.
IEC Technical Committee
core  

PD apparent charge estimation and calibration: a critical review

open access: yes, 2010
This paper focuses on the limits of partial discharge apparent charge estimation and calibration using an unified approach. The fundamental problems that prevent accurate apparent charge estimates (resonances, attenuation and partial discharge pulse ...
CAVALLINI, ANDREA   +5 more
core   +1 more source

Experimental Comparison of Optical Detection Performance for Partial Discharge in GIS: PMT, Fluorescent Fiber and SiPM

open access: yesIET Science, Measurement &Technology, Volume 20, Issue 1, January/December 2026.
This paper presents a systematic comparative experimental study on the response characteristics of three optical detection systems under typical GIS defect discharges. By detecting discharges from five defect types at varying voltages and locations, combined with a comparative analysis using the pulse current method, the practical detection performance
Wei Wang   +5 more
wiley   +1 more source

Label‐Free Partial Discharge Severity Assessment in Gas‐Insulated Switchgear via Semantic‐Guided Unsupervised Domain Adaptation

open access: yesIET Science, Measurement &Technology, Volume 20, Issue 1, January/December 2026.
A semantic‐guided unsupervised domain adaptation network (UDAN) is proposed for label‐free partial discharge severity assessment in gas‐insulated switchgear. The method combines PD measurement signals and inspection‐record semantics to achieve robust cross‐domain condition assessment through feature alignment and adversarial adaptation.
Zhengyang Wu   +6 more
wiley   +1 more source

DGA Distribution Model for Discharging Deterioration of Converter Transformer in Various AC‐DC Composite Voltage Ratios and Statistical Diagnosis

open access: yesThe Journal of Engineering, Volume 2026, Issue 1, January/December 2026.
This paper proposes a statistical DGA diagnosis method to evaluate the occurrence and type of the discharge starting stage of the converter transformer based on a statistical analysis of the gas generation amount in the converter transformer oil during operation.
Kwang Hui An   +2 more
wiley   +1 more source

Home - About - Disclaimer - Privacy