Results 21 to 30 of about 177 (121)

Precision and Accuracy of Pulse Propagation Velocity Measurement in Power Cables

open access: yesEnergies, 2023
The partial discharge (PD) measurement is an important method used in determining the condition of medium- and high-voltage cable insulation. Considering the propagation velocity of PD signals in power cables is necessary for determining the location of ...
Ivar Kiitam   +5 more
doaj   +1 more source

On the Use of Monopole Antennas for Determining the Effect of the Enclosure of a Power Transformer Tank in Partial Discharges Electromagnetic Propagation

open access: yesSensors, 2016
A well-defined condition-monitoring for power transformers is key to implementing a correct condition-based maintenance (CBM). In this regard, partial discharges (PD) measurement and its analysis allows to carry out on-line maintenance following the ...
Ricardo Albarracín   +2 more
doaj   +1 more source

AC Breakdown Voltage and Partial Discharge Activity in Synthetic Ester-Based Fullerene and Graphene Nanofluids

open access: yesIEEE Access, 2022
This paper deals with the study of the AC breakdown voltage (BDV) and partial discharges (PDs) activity of synthetic ester-based nanofluids (NF) with two kinds of carbonic nanoparticles (NPs), namely graphene (Gr) and fullerene (C60); the synthetic ester
Hocine Khelifa   +2 more
doaj   +1 more source

Comparison between the PD Characteristics of g3 and Dry Air for Gas-Insulated Switchgears

open access: yesEnergies, 2022
This paper presents a comparison between the partial discharge (PD) characteristics of g3 and dry air for gas-insulated switchgears. PD signals were measured with a conventional method according to IEC 60270 and an ultra-high frequency (UHF) method.
Goang-Chul Shin   +2 more
doaj   +1 more source

Investigation of sensitivity of the ultra-high frequency partial-discharge detection technology for micro-crack in epoxy insulator in GIS

open access: yesHigh Voltage, 2020
The ultra-high frequency (UHF) method has been widely used in a gas-insulated system (GIS) for partial-discharge detection, and many achievements have been realised.
Jiangrong Cheng   +3 more
doaj   +1 more source

电极结构和油液条件对局部放电的影响

open access: yesDianci bileiqi, 2021
根据IEC 60270标准建立局部放电起始电压(PDIV)测试电路,采用两种方法,即根据IEC61294标准提出IEC方法和根据IEC标准改编的组合PDIV方法,研究了矿物油在针-板电极和针-球电极两种不同电极结构下的局部放电起始电压和局部放电(PD)特性。还研究了不同温度和含水量的Nynas Nytro 4000x矿物油在交流电压下的PDIV和PD特性。试验结果表明,PDIV的大小与电极的电场强度和试验方法有明显关系,与其它电极结构相比,针尖半径为10μm、平面直径为75 mm的针 ...
宋涛, 李丹, 白光亚, 陈少坤
doaj  

Development of an Industrial Partial Discharge Calibrator and Its Performance Tests

open access: yesIEEE Access
In industrial electromechanical manufacturing, ensuring the accuracy of electrical partial discharge measurements is crucial for the reliability and efficiency of electrical power systems.
Ismail Karaman, Ali Ajder, Ismail Nakir
doaj   +1 more source

A Critical Overview of the Impact of Nanoparticles in Ester Fluid for Power Transformers

open access: yesEnergies, 2023
This paper examines the impact of various nanoparticles on ester fluids with a special focus on their usage towards power transformers. The precautionary measures to be considered on the nanofluids such as preparation methodologies with an appropriate ...
Arputhasamy Joseph Amalanathan   +2 more
doaj   +1 more source

DEVELOPMENT AND CALIBRATION OF A MICROCONTROLLER BASED PARTIAL DISCHARGE CALIBRATOR

open access: yesElectrica, 2016
Partial discharge is an instantaneous energy release depending on a charge accumulation caused by an electric field localized in any section of insulation materials. In this phenomenon, there is no observation of full discharge but electrical perforation
Kaan GÜLNİHAR, Mukden UĞUR
doaj   +2 more sources

The effects of drying time during manufacturing process on partial discharge of 83.3 mva 275/160 kv power transformer

open access: yesMATEC Web of Conferences, 2018
Power transformer (PT), essential equipment in electrical power system proceeds complicated manufacturing process to meet high standard design. During manufacturing process of PT, the drying stage is of importance to remove excessive moisture contaminant
Siswanto   +3 more
doaj   +1 more source

Home - About - Disclaimer - Privacy