Karakteristik Peluahan pada Permukaan Akrilik di Sekeliling Elektroda Plat

open access: yesJournal of Energy and Electrical Engineering, 2023
Lebih dari 50% kerusakan pada instrumen sistem daya disebabkan oleh cacat isolator. Cacat isolator ini terkait erat dengan peluahan sebagian karena selain memicu terjadinya kerusakan pada isolator juga bisa menjadi pertanda awal kerusakan isolator.
rian nurdiansyah   +2 more
doaj   +1 more source

Design and Development of a Bio-Inspired UHF Sensor for Partial Discharge Detection in Power Transformers. [PDF]

open access: yesSensors (Basel), 2019
In this paper, the design and development of a bio-inspired UHF sensor for partial discharge detection in power transformers is presented. The UHF sensor was developed for external use in dielectric windows of power transformers.
Nobrega LAMM   +5 more
europepmc   +2 more sources

Analysis of the deterioration process of DC XLPE cable with protrusion defect based on the development of partial discharge. [PDF]

open access: yesPLoS One
High-voltage direct current (HVDC) cables are essential for long-distance power transmission, particularly in renewable energy applications. Cross-linked polyethylene (XLPE) insulation is commonly used in these cables, but protrusion defects that occur ...
Zhou Y   +5 more
europepmc   +2 more sources

Time-Frequency Analysis of Partial Discharge Current Pulses in Different Gas Environment under Lightning Impulse

open access: yesMeasurement Science Review, 2020
This paper deals with a time-frequency analysis of the measured partial discharge (PD) currents in different insulation gases. These gas environments consist of a pure SF6 (sulphur-hexafluoride) and sulphur-hexafluoride and nitrogen (1 % SF6 + 99 % N2 ...
Arikan Kemal, Önal Emel, Şeker Serhat
doaj   +1 more source

IEC 62061:2021-03

open access: yes, 2021
This second edition cancels and replaces the first edition, published in 2005, Amendment 1:2012 and Amendment 2:2015. This edition constitutes a technical revision.
International Electrotechnical Commission
core   +1 more source

On the Use of Monopole Antennas for Determining the Effect of the Enclosure of a Power Transformer Tank in Partial Discharges Electromagnetic Propagation

open access: yesSensors, 2016
A well-defined condition-monitoring for power transformers is key to implementing a correct condition-based maintenance (CBM). In this regard, partial discharges (PD) measurement and its analysis allows to carry out on-line maintenance following the ...
Ricardo Albarracín   +2 more
doaj   +1 more source

Precision and Accuracy of Pulse Propagation Velocity Measurement in Power Cables

open access: yesEnergies, 2023
The partial discharge (PD) measurement is an important method used in determining the condition of medium- and high-voltage cable insulation. Considering the propagation velocity of PD signals in power cables is necessary for determining the location of ...
Ivar Kiitam   +5 more
doaj   +1 more source

AC Breakdown Voltage and Partial Discharge Activity in Synthetic Ester-Based Fullerene and Graphene Nanofluids

open access: yesIEEE Access, 2022
This paper deals with the study of the AC breakdown voltage (BDV) and partial discharges (PDs) activity of synthetic ester-based nanofluids (NF) with two kinds of carbonic nanoparticles (NPs), namely graphene (Gr) and fullerene (C60); the synthetic ester
Hocine Khelifa   +2 more
doaj   +1 more source

Important election information : what is the IEC doing for you? [PDF]

open access: yes, 1994
462.B.2.3(20).pdf created from the media publications in the SA Election material Collection MS 462, held in the Manuscripts Section of the Stellenbosch Library and Information Service.Important election information : what is the IEC doing for you? 1994.

core   +2 more sources

Comparison between the PD Characteristics of g3 and Dry Air for Gas-Insulated Switchgears

open access: yesEnergies, 2022
This paper presents a comparison between the partial discharge (PD) characteristics of g3 and dry air for gas-insulated switchgears. PD signals were measured with a conventional method according to IEC 60270 and an ultra-high frequency (UHF) method.
Goang-Chul Shin   +2 more
doaj   +1 more source