Results 1 to 10 of about 95 (94)
Laboratory stand for development of method and system for continuous non-contact non-destructive testing of technical condition of insulation equipment [PDF]
Measurement of partial discharges (PD) is a generally accepted method of diagnosing the insulation of electrical equipment worldwide. Today, the trend is to move from conventional offline testing to online monitoring to predict the service life of ...
T. G. Galieva +3 more
doaj +1 more source
IEC 60270 Calibration Uncertainty in Gas-Insulated Substations
Accepted Author Manuscript, to cite this publication, please use the final published version with the doi: 10.1109/EIC55835.2023 ...
Mier Escurra, Christian +2 more
openaire +2 more sources
Registrador universal de alta tensión para los laboratorios de ensayo
Tradicionalmente los laboratorios de alta tensión (AT) han precisado diferentes instrumentos de medida para medir las tensiones alternas 50/60 Hz (AC), mediante voltímetros de cresta, impulsos de tensión tipo rayo, mediante medidores de tensiones de ...
Abderrahim Khamlichi +3 more
doaj +1 more source
This paper proposes a fiber optic acoustic sensor (FOAS) based on a single-mode fiber - multimode fiber - single-mode fiber (SMS) structure attached to a thin polymer film used as a diaphragm.
L. G. Pavan Kumar Chaganti +4 more
doaj +1 more source
Karakteristik Peluahan pada Permukaan Akrilik di Sekeliling Elektroda Plat
Lebih dari 50% kerusakan pada instrumen sistem daya disebabkan oleh cacat isolator. Cacat isolator ini terkait erat dengan peluahan sebagian karena selain memicu terjadinya kerusakan pada isolator juga bisa menjadi pertanda awal kerusakan isolator.
rian nurdiansyah +2 more
doaj +1 more source
A synthetic partial discharge (PD) calibrator has been developed to qualify PD analyzers used for insulation diagnosis of HVAC and HVDC grids including cable systems, AIS, GIS, GIL, power transformers, and HVDC converters.
Abderrahim Khamlichi +2 more
doaj +1 more source
In this paper, the practical application of a bio-inspired antenna for partial discharge (PD) detection in high voltage equipment was evaluated in order to validate the efficiency of using this technology for PD monitoring purposes.
Josiel Cruz +7 more
doaj +1 more source
Metrological Qualification of PD Analysers for Insulation Diagnosis of HVDC and HVAC Grids
On-site partial discharge (PD) measurements have turned out to be a very efficient technique for determining the insulation condition in high-voltage electrical grids (AIS, cable systems, GIS, HVDC converters, etc.); however, there is not any ...
Fernando Garnacho +14 more
doaj +1 more source
This paper deals with a time-frequency analysis of the measured partial discharge (PD) currents in different insulation gases. These gas environments consist of a pure SF6 (sulphur-hexafluoride) and sulphur-hexafluoride and nitrogen (1 % SF6 + 99 % N2 ...
Arikan Kemal, Önal Emel, Şeker Serhat
doaj +1 more source
Precision and Accuracy of Pulse Propagation Velocity Measurement in Power Cables
The partial discharge (PD) measurement is an important method used in determining the condition of medium- and high-voltage cable insulation. Considering the propagation velocity of PD signals in power cables is necessary for determining the location of ...
Ivar Kiitam +5 more
doaj +1 more source