MAIA: Technical Development of a Novel System for Video Observations of Meteors
A system for double station observation of meteors now known as MAIA (Meteor Automatic Imager and Analyzer) is introduced in this paper. The system is based on two stations with gigabite ethernet cameras, sensitive image intensifiers and automatic ...
S. Vítek +3 more
doaj
Computed tomography with image intensifier: imaging and characterization of materials
Computed tomographic images, nondestructive evaluation of materials of ceramics, electrical insulators, wood and other samples obtained, using a new tomographic system based on an image intensifier replacing earlier system (Cesareo et al., Nucl.
R Cesareo +5 more
core +1 more source
Multiple-exposure image-intensifier camera. [For photography of detonations]
An image-intensifier camera with light gain of a few thousand times and exposure pulse times as short as 8 ns has been applied to the study of high explosives.
Chiles, W. C. +2 more
core
Application of gain-modulated image intensifier in biomedical imaging
In recent years, the incorporation of image intensifiers into charge-coupled-device (CCD) devices has resulted in intensified CCD (ICCD) systems, which possess high sensitivity in low light conditions, as well as high temporal resolution.
Ho, Jun Hui
core +1 more source
Concept for Image Intensifier with CMOS Imager Output Interface
A concept is described for the detection and location of transient objects, in which a “pixel-binary ” CMOS imager is used to give a very high effective frame rate for the imager.
Paul J. Thomas +3 more
core
Performance of electrostatically-focussed image intensifier tubes in low magnetic fields
97-026 The particle identification system proposed for the LHCÂB experiment is based on RICH counters with three different radiator materials and hybrid photon detectors (HPDs) as a possible readout.
Gys, Thierry
core
The Use of Contrast in Caudal Epidural Injections under Image Intensifier Guidance: Is It Necessary? [PDF]
Naidoo K, Alazzawi S, Montgomery A.
europepmc +1 more source
Detection of articular perforations of the proximal humerus fracture using a mobile 3D image intensifier - a cadaver study. [PDF]
Theopold J +5 more
europepmc +1 more source
Projection-angle-dependent image intensifier distortion correction in high-speed tomography
: The geometric distortion pattern induced by electron deflection in x-ray image intensifiers is strongly influenced by the surrounding magnetic field. Therefore, variations in the magnetic field as sensed by the image intensifier causes the distortion ...
Dirckx, Joris +5 more
core
Modelling of an X-ray image-intensifier-based radiography system
A model will be proposed for predicting the expected value and variance of the measured signal-level in collected radiographic images obtained with an image-intensifier-based X-ray radiography system.
Sandborg, Michael, +2 more
core

