Results 81 to 90 of about 11,253,180 (206)

(Manufacturing of the 40/30 mm gated image intensifier tube)

open access: yes, 1990
One of EG G's customers is attempting to find a manufacturer to make the 40/30 mm gated image intensifier tube. A request for quotation had been sent out to a number of manufacturers.
Vine, B. H.
core   +1 more source

Managing intraoperative fatigue failure of proximal jig for interlocking nail – A case report and technical tip

open access: yesJournal of Orthopaedic Diseases and Traumatology, 2019
Interlocking nails are widely used implants in the management of long-bone diaphyseal fractures. Interlocking nailing is an easy, predictable, and standard method owing to the presence of ancillary instruments and image intensifier. Proximal jigs help in
Binit Singh   +2 more
doaj   +1 more source

3D-profiling by optical demodulation with an image intensifier

open access: yes, 2022
S.191-196 : Ill., Lit.The acquirement of 3D-information is currently achieved by stereophotography, line and grid projection techniques or by laser scanning in combination with a fast distance measuring device.
Wagner, E., Höfler, H., Jetter, V.
core   +1 more source

Directionally-unambiguous, digital particle image velocimetry studies using a image intensifier camera

open access: yes, 1995
The paper describes the implementation of a Digital Particle Image Velocimeter (in the Particle Tracking mode) using an advanced, ultra-high speed gated, image intensifier, monochrome video camera.
Wang, X., Grant, I.
core   +1 more source

Subjective measurement of resolution of image intensifier tubes [PDF]

open access: yes
Limiting resolution is traditionally defined as a spatial frequency of smallest resolvable element of a resolution target that can be distinguish by a human observer.
Chrzanowski, Krzysztof
core   +1 more source

Position and time resolution measurements with a microchannel plate image intensifier: A comparison of monolithic and pixelated CeBr$_3$ scintillators

open access: yes, 2016
To perform Four Dimensional Age Momentum Correlation measurements in the near future, where one obtains the positron lifetime in coincidence with the three dimensional momentum of the electron annihilating with the positron, we have investigated the time
Sperr, Peter   +8 more
core   +1 more source

Quebra de ponta de cânula, no plano gorduroso, durante lipoaspiração Breakage of the tip of the cannula in the adipose tissue during liposuction

open access: yesRevista Brasileira de Cirurgia Plástica, 2012
Durante procedimento de lipoaspiração, uma cânula teve seu segmento distal de 3 cm quebrado no plano adiposo. Os autores apresentam, neste trabalho, a conduta adotada para solução do caso, de maneira simples e rápida, com emprego de um intensificador de ...
Moisés Wolfenson   +2 more
doaj  

X-RAY IMAGE INTENSIFIER FOR NONDESTRUCTIVE TESTING

open access: yes, 1997
提出一种用于工业射线检测的新型X射线图象增强器及其实时成象系统,并给出它们的结构和性能。A new X-ray image intensiFier and a real-time imaging system are put Forward For industrial X-ray nondestructive testing and their structures and perFormances are also ...
林振旺, 杨晓文, 何秀堂
core  

Image-intensifier photography of simulated showers in large-area layers of plastic scintillator

open access: yes, 1968
Preliminary results are presented of some tests which have been made to determine the feasibility of using an image-intensifier camera to photograph showers developing within an ionization calorimeter containing large sheets of plastic scintillator. The
T. Sandor, R. W. Huggett, J. E. Webb
core   +1 more source

Home - About - Disclaimer - Privacy