Results 41 to 50 of about 15,712 (299)

A new topology of the switched-inductor/capacitor quasi Z-source inverter with ability of uplifted-boost [PDF]

open access: yesInternational Journal of Industrial Electronics, Control and Optimization, 2020
In this paper, a new topology of switched-inductor/capacitor quasi impedance source inverter is suggested, which in comparison with the other topologies possesses higher boost voltage inversion at high modulation index and low shoot through duty cycle ...
Alireza Karbalaei   +2 more
doaj   +1 more source

An adaptive virtual impedance fault current limiter for optimal protection coordination of islanded microgrids

open access: yesIET Renewable Power Generation, 2022
Fault currents of inverter‐interfaced distributed generators (IIDGs) depend on inverter controllers. Thus, IIDGs fault currents are different than those of synchronous‐based DGs, both from the magnitude and waveshape perspectives.
Talal Elemamali Sati, Maher A. Azzouz
doaj   +1 more source

Master–slave current regulation of an LCL-filter-based grid-connected inverter under variable grid condition

open access: yesThe Journal of Engineering, 2019
To ease the heavy burden of inverter control, including line current regulation, harmonic current suppression, filter resonance suppression, grid distortion suppression, phase locked loop etc., the study proposes a master–slave current regulation method ...
Yuanbin He   +4 more
doaj   +1 more source

Modeling, Analysis, and Control Design of a Single-Stage Boost Inverter

open access: yesEnergies, 2021
A single-phase, single-stage, differential boost inverter comprises two independently-controlled boost DC-DC converters, with the load connected between their outputs.
Md. Rasheduzzaman   +3 more
doaj   +1 more source

A Simplified Design Strategy for Multi-Resonant Current Control of a Grid-Connected Voltage Source Inverter with an LCL Filter

open access: yesEnergies, 2018
A distorted grid voltage or nonlinear behavior in the current control loop can cause low frequency current harmonics in a grid-connected voltage source inverter (VSI).
Matthias Schiesser   +3 more
doaj   +1 more source

Fault-Tolerant Operation of an Open-End Winding Five-Phase PMSM Drive with Inverter Faults [PDF]

open access: yes, 2013
The authors would like to thank the ADEME for the funding of the MHYGALE project.Multi-phase machines are known for their fault-tolerant capability. However, star-connected machines have no fault tolerance to inverter switch short-circuit fault.
NGUYEN, Ngac Ky   +10 more
core   +1 more source

Research on Dynamic Performance Improvement of Load Switching in Microgrid to Three-phase Voltage Source Inverter Based on LADRC

open access: yes, 2020
The droop-controlled inverter can be modeled as a controllable voltage source with output impedance in series. However, dynamic performance in islanded microgrid mode is highly sensitive to the inverter output impedance.
Fu, Z   +5 more
core   +1 more source

Enhanced Torque Control of a PMSM Supplied by a Four-Leg Voltage Source Inverter Using the Third Harmonic [PDF]

open access: yes, 2008
This paper investigates an electrical drive composed of a four-leg voltage source inverter and a three-phase starconnected surface permanent magnet synchronous machine with concentrated windings. The inverter fourth leg is clamped to the neutral point of
Johan Gyselinck   +5 more
core   +1 more source

Dimethyl fumarate combined with cisplatin at subcytotoxic doses sensitizes cervical cancer toward ferroptosis and apoptosis through GSH restriction and p53 (re)activation

open access: yesMolecular Oncology, EarlyView.
Dimethyl fumarate (DMF) reduces growth of HPV‐positive cervical cancer spheroids and induces ferroptosis in cervical cancer cells via blocking SLC7A11/Glutathione (GSH) axis. Combination of subcytotoxic doses of DMF and cisplatin (CDDP) further suppresses spheroid growth and drives cell death in 2D culture models.
Carolina Punziano   +6 more
wiley   +1 more source

Power quality improvement by using photovoltaic based shunt active harmonic filter with Z-source inverter converter

open access: yesElectrical engineering & Electromechanics, 2022
Introduction. The major source of energy for a long time has been fossil fuels, however this has its drawbacks because of their scarcity, exhaustibility, and impossibility of reusing them.
B. V. Sai Thrinath   +2 more
doaj   +1 more source