Results 91 to 100 of about 282,869 (210)
Electrical Impedance Plethysmography Versus Tonometry To Measure the Pulse Wave Velocity in Peripheral Arteries in Young Healthy Volunteers: a Pilot Study. [PDF]
Wiegerinck AIP +4 more
europepmc +1 more source
Abstract A lack of consensus remains on whether normobaric hypoxia (NH) and hypobaric hypoxia (HH) may differentially impact physiological factors affecting cerebrovascular regulation, particularly with an additional strenuous exercise component. We sought to compare the acute effects of NH and HH on global cerebral blood flow (gCBF) at an altitude ...
Rachel Turner +3 more
wiley +1 more source
Occult hemorrhages after trauma can be present insidiously, and if not detected early enough can result in patient death. This study evaluated a hemorrhage model on 18 human subjects, comparing the performance of traditional vital signs to multiple off ...
Ethan K. Murphy +15 more
doaj +1 more source
Bioelectrical impedance analysis (BIA) is a widely used and an easy-to-apply method for determining body composition. However, its accuracy depends on population-specific equations.
Iuliana Cretescu +3 more
doaj +1 more source
Respiratory acoustical impedance, a new method to measure airway obstruction during quiet breathing, was compared with plethysmography and spirometry in 19 asthmatics undergoing a bronchial inhalation challenge with an allergen.
Perret, C. +6 more
core
Automatic compensation system for impedance measurement [PDF]
This paper deals with the realization of the four-pair terminal definition of impedance standards. A simple, though reliable, system is described that allows an automatic compensation of the voltage at the low potential port of impedance standards to be ...
VALLAN A +12 more
core +1 more source
Abstract Aerobic exercise testing helps facilitate recovery post‐concussion. Current protocols (Calgary Concussion Cycling Test: CCCT) are inaccessible for athletes with lower‐body impairments (i.e. Para athletes). This study compared physiological parameters for a novel arm crank test, the Calgary Adapted aRm Ergometer (CARE) test, with the CCCT ...
Jonathan D. Smirl +12 more
wiley +1 more source
Experimental Study on Impedance Control for the Five-Finger Dexterous Robot Hand DLR-HIT II [PDF]
This paper presents experimental results on the five-finger dexterous robot hand DLR-HIT II, with Cartesian impedance control based on joint torque and nonlinearity compensation for elastic dexterous robot joints.
Wimböck, Thomas +13 more
core +1 more source
Objective: This study evaluated the impact of feet callosities, arm posture, and use of electrolyte wipes on body composition measurements by bioelectrical impedance analysis (BIA) in morbidly obese adults.
Jessica Roekenes +3 more
doaj +1 more source
Printed textile-based dry electrodes for impedance plethysmography measurements
In this work, we report on the design, fabrication, and characterization of dry electrodes for the measurement of pulse plethysmography signals from distal arteries via electrical impedance.
Altana A. +9 more
core +1 more source