Results 131 to 140 of about 3,866 (181)
Some of the next articles are maybe not open access.

Comparison of electrical field plethysmography with electrical impedance plethysmography

Annals of Biomedical Engineering, 1982
As a means for assessing cardiac function, electrical field plethysmography (EFP) has been shown to have some features quite different from electrical impedance plethysmography (EIP). Here the two techniques are compared by using the two systems simultaneously on a subject and also with independent use in different electrode configurations. The results
S K, Guha, S, Anand
openaire   +2 more sources

Differential impedance plethysmography for measuring thoracic impedances

Medical & Biological Engineering & Computing, 1982
A critical evaluation of the measurement of the transthoracic basic impedance Zo according to Kubicek's method revealed inhomogeneous electrical field-distributions in the region of the neck and the shoulders and in the region of the mammae in female subjects. These inhornogeneties were found to introduce uncontrollable errors, like position dependency
J H, Meijer   +5 more
openaire   +2 more sources

Features of Pulse Plethysmography and a Comparison with Impedance Plethysmography

Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 1992
The features of current pulse plethysmography are given. The skin capacitance and resistance are depending upon pulse duration but not the internal resistance. The internal resistance changes depend of arteries volume changes. A comparison between pulsed plethysmography and sine-wave plethysmography is discussed.
null Santic, null Saban
openaire   +2 more sources

Meaning of Impedance Plethysmography

Nature, 1967
IMPEDANCE plethysmography is a method of measuring the resistive impedance of a limb segment. Nyboer1 pointed out that the resistive impedance variation ΔR during the heart cycle is proportional to the blood volume ΔV transiently stored in the segment where ρ is the blood ...
U. BECATTINI, M. DELLA CORTE
openaire   +1 more source

Impedance Plethysmography: Correlation with Contrast Venography

Radiology, 1977
Impedance plethysmography is a noninvasive, indirect test for deep venous occlusion in the lower limbs. The results of ascending contrast venography impedance plethysmography have been compared in 315 limbs. Impedance plethysmography was positive in 77 of 79 limbs with acute deep vein thrombosis proximal to the calf.
K T, Benedict   +2 more
openaire   +2 more sources

IMPEDANCE PLETHYSMOGRAPHY IN STUDY OF PERIPHERAL CIRCULATION

Archives of Surgery, 1952
DIGITAL pulse volume studies have proved of great value in the study of the peripheral circulation. The methods most commonly used have the disadvantage that they necessitate placing the digit in an airtight or watertight cylindrical compartment. In most of them the tracings are recorded on photographic paper, and analysis of data must wait until the ...
W S, COXE, H B, SHUMACKER, L W, FREEMAN
openaire   +2 more sources

Impedance Plethysmography

Plastic and Reconstructive Surgery, 1991
Vigilant postoperative monitoring of the buried muscle flap is critical after free transfer because early diagnosis of vascular insufficiency is essential to allow prompt correction. We have identified a monitoring method utilizing needle electrodes and impedance plethysmography that gives a beat-to-beat representation of muscular perfusion.
M J, Concannon   +3 more
openaire   +2 more sources

Positional Factors in Venous Impedance Plethysmography

Archives of Surgery, 1973
To determine whether leg position or distance between the inner electrodes affect the magnitude of impedance change during deep inspiration, 30 adult patients (60 limbs) were studied with the Minnesota Impedance Cardiograph. Phlebography was performed in 19 limbs and correlated with the impedance findings.
F E, Deuvaert   +2 more
openaire   +2 more sources

Electrical Impedance Plethysmography

Archives of Internal Medicine, 1962
Plethysmography has proven to be a valuable method for studying the dynamics of peripheral vascular beds in normal and pathologic states and for evaluating the effects of drugs upon these beds. Refinements of the method, such as graded outflow hindrance and stopflow studies, have permitted separation of the pulsatile arterial inflow and venous runoff ...
openaire   +1 more source

Impedance plethysmography on the arms: Respiration monitoring

2010 IEEE International Conference on Bioinformatics and Biomedicine Workshops (BIBMW), 2010
A new method for extracting respiratory rate from electrical impedance measured on the arms is presented. The method requires application of only four electrodes to the subject's arms and is suitable to be used in a portable respiratory rate monitor and decision making systems. Set-Membership filtering is used to reduce the effect of motion artifact on
Sardar Ansari   +3 more
openaire   +1 more source

Home - About - Disclaimer - Privacy