Results 271 to 280 of about 628,326 (292)
Some of the next articles are maybe not open access.
IEEE PES Asia-Pacific Power and Energy Engineering Conference
To suppress the harmonic resonance in AC integrated offshore wind farm, this paper investigates the suppression method based on the STATCOM installed at the onshore control center.
Xiaoming Huang +7 more
semanticscholar +1 more source
To suppress the harmonic resonance in AC integrated offshore wind farm, this paper investigates the suppression method based on the STATCOM installed at the onshore control center.
Xiaoming Huang +7 more
semanticscholar +1 more source
2024 IEEE 7th International Electrical and Energy Conference (CIEEC)
In recent years, impedance-based stability analysis and improvement methods have become very popular in DC distribution systems. However, the existing stability criteria such as the impedance-ratio and impedance-sum criteria, require the additional ...
Yong Chen +5 more
semanticscholar +1 more source
In recent years, impedance-based stability analysis and improvement methods have become very popular in DC distribution systems. However, the existing stability criteria such as the impedance-ratio and impedance-sum criteria, require the additional ...
Yong Chen +5 more
semanticscholar +1 more source
Virtual Positive-Damping Reshaped Impedance Stability Control Method for the Offshore MVDC System
IEEE Transactions on Power Electronics, 2019For the offshore MVDC system, the DC-side medium voltage can easily cause high-frequency oscillation and even instability owing to the complex impedance interactions. The virtual-resistance stability control aiming at rectifier station is introduced from low-voltage DC micro-grid application for mitigating its DC-side oscillation without affecting the ...
Leming Zhou +8 more
openaire +1 more source
2013 IEEE Power & Energy Society General Meeting, 2013
This paper analyzes and investigates the effect of a voltage-source converter (VSC) on subsynchronous resonance and system damping interaction in a series-compensated system with multi-mass synchronous generator. The incremental output impedance/admittance of a VSC that is constructed by the circuit components and control parameters of a VSC is the key
Khaled Mohammad Alawasa +2 more
openaire +1 more source
This paper analyzes and investigates the effect of a voltage-source converter (VSC) on subsynchronous resonance and system damping interaction in a series-compensated system with multi-mass synchronous generator. The incremental output impedance/admittance of a VSC that is constructed by the circuit components and control parameters of a VSC is the key
Khaled Mohammad Alawasa +2 more
openaire +1 more source
IEEE transactions on industry applications
Constant power loads (CPLs) are converter-based loads that cause overloading or underloading of specific components in the DC Microgrid (DC MG) system, there by exacerbating stability issues.
Rohit Kumar Rastogi, Manoj Tripathy
semanticscholar +1 more source
Constant power loads (CPLs) are converter-based loads that cause overloading or underloading of specific components in the DC Microgrid (DC MG) system, there by exacerbating stability issues.
Rohit Kumar Rastogi, Manoj Tripathy
semanticscholar +1 more source
Oscillation Mitigation Based on Impedance Reshaping of MMC-HVDC
2023Weisheng Wang, Guanghui Li, Guoqing He
openaire +1 more source
Oscillation Mitigation Based on the Impedance Reshaping of SVG
2023Weisheng Wang, Guanghui Li, Guoqing He
openaire +1 more source
Applied Power Electronics Conference
Grid Forming converters (GFM), based on virtual synchronous machine, Synchronverter, and droop-based control, provide an inductive impedance behaviour at the Point of Common Coupling (PCC). A controller has very limited capability to shape this inductive
C. Shah +3 more
semanticscholar +1 more source
Grid Forming converters (GFM), based on virtual synchronous machine, Synchronverter, and droop-based control, provide an inductive impedance behaviour at the Point of Common Coupling (PCC). A controller has very limited capability to shape this inductive
C. Shah +3 more
semanticscholar +1 more source
Oscillation Mitigation Based on Impedance Reshaping of REG Unit
2023Weisheng Wang, Guanghui Li, Guoqing He
openaire +1 more source
2024 IEEE 10th International Power Electronics and Motion Control Conference (IPEMC2024-ECCE Asia)
The grid-following control strategy based on phase-locked loops (PLL) is widely used in doubly-fed induction generator (DFIG) systems. However, the PLL will lead to frequency coupling as well as negative resistance characteristics, which may worsen the ...
Bochen Luo +3 more
semanticscholar +1 more source
The grid-following control strategy based on phase-locked loops (PLL) is widely used in doubly-fed induction generator (DFIG) systems. However, the PLL will lead to frequency coupling as well as negative resistance characteristics, which may worsen the ...
Bochen Luo +3 more
semanticscholar +1 more source