Results 211 to 220 of about 128,845 (282)

Real‐Time In Vivo Monitoring of Anastomotic Intestinal Ischemia Using Implantable Resorbable Organic Sensors

open access: yesAdvanced Science, EarlyView.
Resorbable impedance sensors are successfully implanted into porcine small intestinal anastomoses. Impedance was recorded for 2 hours prior, and 2 hours following ischemia induction, and a significant drop in tissue impedance was observed. Abstract Anastomotic failure remains one of the most severe complications in gastrointestinal surgery.
Dennis Wahl   +12 more
wiley   +1 more source

From Grave to Cradle: Kombucha Waste for Sustainable Electronics

open access: yesAdvanced Science, EarlyView.
This study introduces a sustainable method to purify kombucha bacterial cellulose (KBC) with sodium bicarbonate and hydrogen peroxide, avoiding harsh chemicals. KBC films are patterned with gold and function as pressure sensors for flatfoot gait detection. At the end‐of‐life, the KBC‐based device biodegrades in soil, leaving environmentally benign gold
Xin Ying Chan   +6 more
wiley   +1 more source

Data-driven simulations to assess the impact of study imperfections in time-to-event analyses. [PDF]

open access: yesAm J Epidemiol
Abrahamowicz M   +6 more
europepmc   +1 more source

Principles for Rigorous Design and Application of Synthetic Microbial Communities

open access: yesAdvanced Science, EarlyView.
SynComs are artificially designed to enable inter‐species metabolic interactions, metabolic division of labor, and ecological interactions that can elicit phenotypes like colonization stability and environmental adaptation. This systematic review explores the processes used to construct SynComs, the assessment of the mechanisms of metabolic interaction
Yuxiao Zhang   +21 more
wiley   +1 more source

Super‐Robust Telecommunications Enabled by Topological Half‐Supermodes

open access: yesAdvanced Science, EarlyView.
Through topological half‐supermode engineering, we realize a valley‐ridge gap waveguide that is directly compatible with conventional waveguides and features topological protection. This design halves the lateral size via a PEC boundary, enabling direct TE₁₀‐mode matching and robust bend‐immune transmission.
Rui Zhou   +8 more
wiley   +1 more source

Imperfection in Semiconductors Leading to High Performance Devices

open access: yesAdvanced Science, EarlyView.
Crystalline perfection is typically pursued in semiconductors to enhance device performance. However, through modeling and experimental work, we show that defects can be strategically employed in a specific detection regime to increase sensitivity to extreme values. GaN diodes are demonstrated to effectively detect high‐energy proton beams at fluxes as
Jean‐Yves Duboz   +8 more
wiley   +1 more source