Results 101 to 110 of about 202,406 (286)

A Bespoke Programmable Interpenetrating Elastomer Network Composite Laryngeal Stent for Expedited Paediatric Laryngotracheal Reconstruction

open access: yesAdvanced Functional Materials, EarlyView.
A programmable interpenetrating double‐network architecture, created via 3D‐TIPS printing and resin infusion, synergistically combines thermoplastic and thermosetting elastomers to balance structural rigidity and surface softness—crucial for paediatric laryngeal stents.
Elizabeth F. Maughan   +14 more
wiley   +1 more source

Approaches of wearable and implantable biosensor towards of developing in precision medicine

open access: yesFrontiers in Medicine
In the relentless pursuit of precision medicine, the intersection of cutting-edge technology and healthcare has given rise to a transformative era. At the forefront of this revolution stands the burgeoning field of wearable and implantable biosensors ...
Elham Ghazizadeh   +7 more
doaj   +1 more source

Reticular telangiectatic erythema: case report and literature review

open access: yesDermatology Practical & Conceptual, 2015
Background: Reticular telangiectatic erythema is a benign cutaneous reaction that may occur in patients who have received a subcutaneous implantable cardioverter-defibrillator.
Bryce D. Buetler, Philip R. Cohen
doaj   +1 more source

Automatic Mode Switching in Atrial Fibrillation [PDF]

open access: yes, 2005
Automatic mode switching (AMS) algorithms were designed to prevent tracking of atrial tachyarrhythmias (ATA) or other rapidly occurring signals sensed by atrial channels, thereby reducing the adverse hemodynamic and symptomatic consequences of a rapid ...
Antonio De, Simone   +2 more
core  

A Smart Bio‐Battery Facilitates Diabetic Bone Defect Repair Via Inducing Macrophage Reprogramming and Synergistically Modulating Bone Remodeling Coupling

open access: yesAdvanced Functional Materials, EarlyView.
This research presents a novel implantable bio‐battery, GF‐OsG, tailored for diabetic bone repair. GF‐OsG generates microcurrents in high‐glucose conditions to enhance vascularization, shift macrophages to the M2 phenotype, and regulate immune responses.
Nanning Lv   +10 more
wiley   +1 more source

Towards an Implantable, Low Flow Micropump That Uses No Power in the Blocked-Flow State

open access: yesMicromachines, 2016
Low flow rate micropumps play an increasingly important role in drug therapy research. Infusions to small biological structures and lab-on-a-chip applications require ultra-low flow rates and will benefit from the ability to expend no power in the ...
Dean G. Johnson, David A. Borkholder
doaj   +1 more source

Ultrahigh‐Yield, Multifunctional, and High‐Performance Organic Memory for Seamless In‐Sensor Computing Operation

open access: yesAdvanced Functional Materials, EarlyView.
Molecular engineering of a nonconjugated radical polymer enables a significant enhancement of the glass transition temperature. The amorphous nature and tunability of the polymer, arising from its nonconjugated backbone, facilitates the fabrication of organic memristive devices with an exceptionally high yield (>95%), as well as substantial ...
Daeun Kim   +14 more
wiley   +1 more source

Mortality and Costs of Cardiac Implantable Electronic Device (CIED) Infections According to the Therapeutic Approach: A Single-Center Cohort Study

open access: yesMicroorganisms
Background: Cardiac device infections are serious adverse events associated with considerable morbidity and mortality, significant costs, and increased healthcare utilization.
Encarnación Gutiérrez-Carretero   +5 more
doaj   +1 more source

Consumed by Abdominal Distention

open access: yes
Arthritis Care &Research, EarlyView.
Abimbola Fadairo‐Azinge   +3 more
wiley   +1 more source

In Situ Study of Resistive Switching in a Nitride‐Based Memristive Device

open access: yesAdvanced Functional Materials, EarlyView.
In situ TEM biasing experiment demonstrates the volatile I‐V characteristic of MIM lamella device. In situ STEM‐EELS Ti L2/L3 ratio maps provide direct evidence of the oxygen vacancies migrations under positive/negative electrical bias, which is critical for revealing the RS mechanism for the MIM lamella device.
Di Zhang   +19 more
wiley   +1 more source

Home - About - Disclaimer - Privacy