Results 51 to 60 of about 197,962 (295)
Feasibility and Limitations of the Advanced Replica Process for Bioactive Glasses
Periodic 3D‐printed Kelvin‐cell templates enable a controlled advanced replica process for fabricating highly porous glass lattices. Across P45K9, 45S5, and 13–93, material‐dependent differences in coating, burnout, and shrinkage lead to distinct strut morphologies, while comparable final porosities of 83%–88% are retained.
Swantje Funk +4 more
wiley +1 more source
Multimode and Multiband Microstrip Antennas [PDF]
This thesis describes original work on the broadband and multiband matching of microstrip patch antennas. Microstrip patch antennas suffer from many constraints on their performance. One major restriction is their narrow impedance bandwidth.
Abunjaileh, Alaa Ibrahim
core +4 more sources
The leadless cardiac pacemaker is a revolutionary device for bradycardia patients. It is a single-component, capsule-type implantable medical device that corrects the heart's electrical function when the heart rate falls below the standard value ...
Deepti Sharma +2 more
doaj +1 more source
This study proposes a potential device design for joint cartilage replacement. Silica‐polytetrahydrofuran (SiO2‐PolyTHF) hybrids with customizable mechanical properties were developed to mimic the characteristics of a natural meniscus. These were synthesized through a two‐pot sol–gel hybrid process.
Yu‐Chien Lin +12 more
wiley +1 more source
ABSTRACT Chitosan, a polysaccharide upcycled from biowaste, has long promised sustainable, biocompatible, and antimicrobial films and devices, an appeal reinforced by its recent regulatory recognition, with several chitosan‐based antibacterial dressings gaining clearance through the Food and Drug Administration's 510(k) pathway.
Jacopo Nicoletti +16 more
wiley +1 more source
Fully additive vertical organic electrochemical transistors (vOECTs) with channel‐length of 226 nm on a 50 µm compostable substrate achieve >106 current modulation and ∼36 mS transconductance. Ion‐selective integration enables 1.1 mA dec−1 sensitivity and 36 µm detection limit, highlighting a scalable platform for sustainable electronics and ...
Giulia Frusconi +3 more
wiley +1 more source
Implantable medical devices (IMDs) are revolutionizing healthcare by enabling continuous monitoring, targeted treatment, and improved quality of life for patients with chronic conditions.
Mosab Jasim +5 more
doaj +1 more source
A dynamically actuated reconfigurable topographical surface (DARTS) integrates contact‐mediated bactericidal nanotopography with programmable mechanical actuation to actively disrupt bacterial biofilms. Dynamic surface reconfiguration enhances bacterial killing and suppresses implant‐associated infections in vivo, providing a new strategy for active ...
Mohammad Asadi Tokmedash +4 more
wiley +1 more source
Guest Editorial: Special Cluster on Antennas for Wireless Body Area Networks
The papers in this special section highlight current and emerging research in antennas for WBAN, as well as applications of this technology. This ssection brings together the latest work in antennas for in-, on-, and off-body communication, the WBAN ...
Skrivervik, A +3 more
core +1 more source
Miniature implantable antennas for biomedical telemetry: From simulation to realization [PDF]
WOS:000310154700019 (Nº de Acesso Web of Science)“Prémio Científico ISCTE-IUL 2013”We address numerical versus experimental design and testing of miniature implantable antennas for biomedical telemetry in the medical implant communications service band ...
Nikita, Konstantina S. +4 more
core +1 more source

