Results 121 to 130 of about 96,798 (264)
Radiation therapy of a patient with implantable cardioverter defibrillator [PDF]
A number of patients who require radiation therapy may suffer from different comorbidities. Cardiac rhythm disturbances represent a comorbidity which in terms may require the implantation of a permanent pacemaker or an implantable cardioverter ...
Kyriakogiannaki, Ariadni +4 more
core
Ventricular tachyarrhythmias and implantable cardioverter–defibrillator
Few scenarios in intensive coronary care are commonly associated with as much fear and apprehension as the event of a ventricular tachyarrhythmia. This chapter provides information to help successfully manage such situations.
Stefan H Hohnloser, Joachim R Ehrlich
core +1 more source
An implantable cardioverter defibrillator in a patient with triple mechanical valves
Key Clinical Message A patient with permanent atrial fibrillation, triple mechanical prosthetic valve replacements, and nonischemic cardiomyopathy presented with symptomatic high‐grade atrioventricular block.
Alex W. X. Tan +3 more
doaj +1 more source
ABSTRACT Introduction In patients with ischemic cardiomyopathy (ICM), recurrent VF may be treated with catheter ablation by targeting triggering premature ventricular complexes (PVCs) and/or ventricular scar homogenization. Data on optimal ablation strategies in patients with non‐ischemic cardiomyopathy (NICM) remain limited.
Kenji Hashimoto +2 more
wiley +1 more source
Patients with an implantable cardioverter defibrillator (ICD) show clinically relevant depression and anxiety, but little is known about their levels of posttraumatic stress.
von Känel, R. +14 more
core +1 more source
ABSTRACT Background Drug‐refractory ventricular tachycardia (VT) after failed radiofrequency (RF) ablation remains a clinical challenge. Pulsed‐field ablation (PFA) is expanding to ventricular applications, but United States experience with focal pulsed‐field‐only catheters in VT is sparse, and pulsed‐field platforms are not equivalent across ...
Jorge L. Reyes +3 more
wiley +1 more source
Impact of coils and fixation mechanism on implantable cardioverter defibrillator lead extraction
Background: Percutaneous removal of implantable defibrillator (ICD) leads remains a difficult procedure, despite the fact that extraction techniques have been improved and advances in lead technology have been made in order to reduce fibrous tissue ...
R. De Lucia +9 more
core
Because of multiple ventricular lead fractures with inappropriate shocks, a 31-year-old male received a completely subcutaneous implantable cardioverter defibrillator (ICD) system with the already existing 'endocardial' ICD functioning as an atrial ...
van Opstal, Jurren +5 more
core +1 more source
ABSTRACT Background Pulsed field ablation (PFA) is an emerging non‐thermal ablation modality with proven safety in atrial arrhythmia ablation. However, data on its performance for ventricular arrhythmias (VA) remain limited. Objective To evaluate the feasibility, safety, and efficacy of PFA for complex VA in a multicenter real‐world US registry ...
Narut Prasitlumkum +22 more
wiley +1 more source
Validation of Cardiorespiratory‐Gated Proton Beam Delivery for Stereotactic Arrhythmia Radioablation
Stereotactic arrhythmia radioablation (STAR) with scanned proton beams was performed in a porcine model targeting the left ventricular free wall (A). Dual gating synchronized proton delivery with both respiratory and cardiac motion was compared to single gating using only respiratory motion (B).
Jagdip Kang +17 more
wiley +1 more source