Results 91 to 100 of about 11,060 (223)

Implantable cardioverter defibrillators: state of the art

open access: yesResearch Reports in Clinical Cardiology, 2015
Jordan C Ray, Harrison M Goodall, Thomas E Pascual, Fred M Kusumoto Electrophysiology and Pacing Service, Division of Cardiovascular Disease, Department of Medicine, Mayo Clinic, Jacksonville, FL, USA Abstract: It has been estimated that 180,000&ndash ...
Ray JC   +3 more
doaj  

QT Interval Evaluation in Right Ventricular Pacing: Validation of a Novel Formula

open access: yesPacing and Clinical Electrophysiology, EarlyView.
Abstract Background QT interval measurement in the presence of right ventricular pacing (RVP) represents a clinical challenge. We therefore aimed to derive and validate a formula for QT estimation during RVP in a large cohort of pacemaker patients. Methods and Results We prospectively enrolled 100 patients in a derivation cohort and 487 in a validation
Amr Abdin   +9 more
wiley   +1 more source

Safety and Performance of INVICTA DF4 Ventricular Defibrillation Lead: Results From APOLLO Prospective Multicenter Study

open access: yesPacing and Clinical Electrophysiology, EarlyView.
Abstract Background Implantable cardioverter‐defibrillator (ICD) therapy relies on reliable right ventricular leads for pacing, sensing, and defibrillation. The INVICTA DF4 lead is an active‐fixation, quadripolar design intended to optimize implant workflow and long‐term safety and performance. Methods APOLLO was a prospective, multicenter, single‐arm,
Klaus K. Witte   +13 more
wiley   +1 more source

First Experience With Extravascular Implantable Cardioverter‐Defibrillator Under Deep Sedation

open access: yesPacing and Clinical Electrophysiology, EarlyView.
ABSTRACT Background The Extravascular Implantable Cardioverter‐Defibrillator (EV‐ICD) utilizes a substernal lead to provide defibrillation and anti‐tachycardia pacing (ATP) while avoiding transvenous complications. General anesthesia (GA) was applied for implantation procedures in the EV‐ICD pivotal trial and is currently recommended by the ...
Nibras Soubh   +9 more
wiley   +1 more source

Impact of ICD Presence in Patients With Left Ventricular Assist Devices for End‐Stage Heart Failure

open access: yesPacing and Clinical Electrophysiology, EarlyView.
ABSTRACT Background The prognostic relevance of implantable cardioverter defibrillator (ICD) in patients with end‐stage heart failure (HF) with left ventricular assist device (LVAD) remains controversial. Objectives To evaluate the prognostic impact of ongoing use of ICD and associated complications in HF‐patients with LVAD‐implantation.
Nafilah Baridwan   +11 more
wiley   +1 more source

Remote Monitoring of Implantable Cardioverter Defibrillator

open access: yesIndian Pacing and Electrophysiology Journal, 2006
The rate of implantable cardioverter defibrillator (ICD) implantation has gone up as primary and secondary prevention trials have relatively consistently shown significant improvement in mortality and morbidity.
Dwight W. Reynolds   +2 more
doaj  

Implantable cardioverter defibrillators for primary prevention in cardiomyopathies

open access: yesIndian Heart Journal
Background: Implantable cardioverter defibrillators (ICD) are often used as primary prevention strategy for sudden cardiac death (SCD) in young individuals.
Vineetha Kanneganti   +3 more
doaj   +1 more source

Transvenous Lead Extraction Versus Abandonment of non‐Infected, Superfluous Leads—A Meta‐Analysis and Systematic Review

open access: yesPacing and Clinical Electrophysiology, EarlyView.
ABSTRACT Background Managing non‐functional cardiac implantable electronic device (CIED) leads remains controversial. While extraction is standard for infection, it is unclear whether transvenous lead extraction (TLE) or lead abandonment (LA) provides superior outcomes for superfluous leads.
Karanjeet Chauhan   +8 more
wiley   +1 more source

Inpatient Cardiac Resynchronization Therapy During Heart Failure Hospitalization: A Distinct High‐Risk Phenotype

open access: yesPacing and Clinical Electrophysiology, EarlyView.
ABSTRACT Background The role of cardiac resynchronization therapy (CRT) during hospitalization for heart failure (HFH) is uncertain, because hospitalized patients were routinely excluded from landmark CRT trials. Despite this, CRT implantation during HFH is common.
Oliver Rees   +5 more
wiley   +1 more source

Advanced Conduction Disease After Incident Heart Failure in Myotonic Dystrophy Type 1

open access: yesPacing and Clinical Electrophysiology, EarlyView.
Central Figure. Advanced Conduction Disease After Incident HF in Myotonic Dystrophy Type 1. ABSTRACT Background Myotonic dystrophy type 1 (DM1) is associated with progressive cardiac conduction disease, heart failure (HF) and increased mortality. However, the association of incident HF with conduction disease and survival in DM1 is not well defined ...
Isadora Guarino   +3 more
wiley   +1 more source

Home - About - Disclaimer - Privacy