Background: Refractive eye are the most common people eye complaints and there are different ways to refractive correction. In this study we compare the effect of two phakic intraocular lenses, Artiflex versus Implantable Contact Lens (ICL).
Sayyed Mohammad Ghoreishi +4 more
doaj +1 more source
Evaluation of the central vault following implantable phakic contact lens and its correlation to horizontal white to white corneal diameter by anterior segment optical coherence tomography [PDF]
Background: Implantable Phakic Contact Lenses have been developed as a cost-effective alternative to Visian Implantable Collamer lenses for refractive correction.
Hatem Samy +2 more
doaj +1 more source
Anatomical and Visual Effects of Implantable Phakic Contact Lens on Correction of Myopia [PDF]
Abstract Purpose: To evaluate the anatomical effects of implantable phakic contact lens (IPCL) (Care Group, India) on anterior segment and its visual outcomes .Patients and methods: In a prospective interventional case series study, 60 highly myopic eyes of 32 patients were subjected to IPCL implantation in the Ophthalmology Department of Minia
Mahmoud Ekram +3 more
openaire +1 more source
Cystoid macular edema associated with omidenepag isopropyl in a phakic eye with an implantable collamer lens: a case report [PDF]
Background Cystoid macular edema is a known complication of omidenepag isopropyl usage. Omidenepag isopropyl is a selective prostanoid EP2 receptor agonist, and its association with macular edema has mainly been identified in pseudophakic eyes.
Byung-Jin Bae +2 more
core +2 more sources
Initial Results From a New Model of Posterior Chamber Implantable Phakic Contact Lens: IPCL V2.0. [PDF]
The aim of this study was to evaluate the corneal safety, intraocular pressure (IOP), vault and refractive efficiency of the new implantable phakic contact lens, IPCL V2.0 (Care Group, India). A prospective case series study was performed to evaluate 100
Bianchi GR.
europepmc +3 more sources
Purpose: To compare clinical outcomes following implantation of two types of posterior chamber phakic intraocular lenses: Visian™ Implantable Collamer Lens with Centraflow (ICL, V4C Staar Surgical, Nidau, Switzerland) and Implantable Phakic Contact Lens (
Gitansha Shreyas Sachdev +4 more
doaj +1 more source
Four-step treatment of keratoconus associated with high refractive ametropia
Relevance. Today, the problem is particularly relevant for cases of keratoconus combined with high refractive ametropia. An extensive review of protocols for the combined use of corneal cross-linking (CXL) in combination with photorefractive keratotomy ...
P. Maharramov
doaj +1 more source
An international survey of daily disposable contact lens prescribing
Free to read\ud \ud Purpose\ud \ud The aim was to determine the extent of daily disposable contact lens prescribing worldwide and to characterise the associated demographics and fitting patterns.\ud \ud Methods\ud \ud Up to 1,000 survey forms were sent ...
Morgan, Philip B. +3 more
core +2 more sources
Corneal Endothelial Changes Following Implantable Collamer Lens Implantation [PDF]
Background: Several studies were conducted over an extended period to rectify refractive defects. This was done by traditional methods like spectacles and contact lenses (CL) or via refractive procedures, which have come to be an acceptable option for ...
Anas Mohamed, Adel Osman, Ahmed Mohamed
doaj +1 more source
ABSTRACT Purpose To evaluate the long‐term (> 1 year) outcomes of vision and intraocular pressure (IOP) control in dogs with glaucoma undergoing combined endoscopic cyclophotocoagulation (ECP) and Ahmed valve gonioimplantation (AVG). Methods Medical records between 2020 and 2025 were reviewed. Outcomes evaluated included IOP control (< 25 mmHg), vision
Sanskruti S. Potnis +6 more
wiley +1 more source

