Results 11 to 20 of about 99,324 (303)
Introduction: An implant-supported prosthesis requires a precise imprint to provide a good fit. It has been suggested that for implant/abutment level impressions, both the indirect (closed tray) and direct (open tray) methods are effective in achieving a
Ashwin N Aidasani +5 more
doaj +2 more sources
Background: The current study examined the accuracy of casts generated using direct impression processes with and without splints for multiple dental implants utilizing two different splinting materials and impression materials.
Milap Karia +7 more
doaj +2 more sources
Drug and dental impression materials
Guidelines to prevent cross contamination with infectious agents have been instituted for dental clinical and laboratory procedures. However, compliance by dental offices and clinics in disinfecting impression material has not been universal.
Sudhakara V Maller +5 more
doaj +2 more sources
Dimensional accuracy of three impression materials by one-step and two-step impression techniques: An in vitro study [PDF]
Introduction: An accurate impression is essential to create a well-fitted dental prosthesis. This study aimed to compare the dimensional accuracy of three elastomeric materials using one-step and two-step impression techniques. Methods: In this study, 20
Zahra Afshari +4 more
doaj +3 more sources
Laboratory investigation of Accuracy of Impression Materials for Border Molding [PDF]
Introduction: Border molding of the edge of the individual impression tray is an important stage of prosthetic treatment of edentulous jaws, which often depends on the final result of the treatment. Classical thermoplastic impression materials for border
Dobromira Shopova, Diyan Slavchev
doaj +4 more sources
Evaluation of Elastomeric Impression Materials’ Hydrophilicity: An in vitro Study [PDF]
Introduction: Hydrophilicity of dental impression materials is crucial for obtaining an accurate impression and necessary for the production of a well-fitting cast restoration. The most common technique for evaluation of hydrophilicity is a contact angle
Anna Theocharidou +3 more
doaj +2 more sources
Purpose: The purpose of this in-vitro study was to evaluate the effect of 0.5% glutaraldehyde spray disinfection on surface wettability of vinyl polysiloxane and polyether impression materials. Methods and materials: Thirty-six specimens were prepared of
Sahar AlZain
doaj +3 more sources
Health Risks Related to Impression Procedures in Dentistry
There is a lot of risks of methods used for impressions, which could be bent out or minimized. They are divided in risks evocated by impression materials and risks related to impression procedures.
Z. Zdráhal +2 more
doaj +2 more sources
Dimensional accuracy of vinyl polyether and polyvinyl siloxane impression materials in direct implant impression technique for multiple dental implants [PDF]
Purpose The present study compared the dimensional accuracy of vinyl polyether silicone (VPES) and polyvinyl siloxane (PVS) impression materials used for non-splinted (NS) and splinted (S) direct open-tray impression techniques for multiple implants ...
Rohini Rajendran +3 more
doaj +2 more sources
Aim of the Study: To evaluate and compare the linear dimensional changes of the three representative polyvinyl siloxane (PVS) impression materials and to compare the accuracy of single mix with double mix impression technique.
Nirmala Kumari, D B Nandeeshwar
doaj +2 more sources

