Results 41 to 50 of about 13,873 (197)
Background: The use of electronic portal imaging devices (EPIDs) is a method for the dosimetric verification of radiotherapy plans, both pretreatment and in vivo.
Ali Jomehzadeh +3 more
doaj +1 more source
Conjugated poly(imide dioxime)‐based microspheres establish a radiometal coordination‐driven conformational interlocked network with ultra‐high radiostability. This platform enables low‐temperature, multi‐radionuclide labeling for SPECT/PET/MRI imaging and radionuclide therapy. Mechanistic insights from EXAFS and DFT reveal enhanced stability, while in
Xiao Xu +10 more
wiley +1 more source
This paper describes a new real-time, in vivo, noninvasive, biasless detector system acting as a beam monitoring and relative dose measurement system.
G A Pablo Cirrone +12 more
doaj +1 more source
Toward Personalized Theranostics: A Modular PET Platform for Antibody‐Based Imaging and Therapy
This modular, site‐specific antibody platform enables customizable conjugates for PET imaging and therapy. Interchangeable payloads – including radiometals, cytotoxics, and fluorophores – support adaptable, multimodal applications with limited off‐target effects. In vivo, the DFO/DOTAGA bischelate immunoconjugate provided clear tumor delineation in PET/
Delphine Vivier +16 more
wiley +1 more source
Deployment of an In Vivo Dosimetry Program with P-Type Diodes for Radiotherapy Treatments
Background: We present the implementation of an in vivo dosimetry program that enhances treatment setups, ensuring high accuracy that is needed globally.
Miguel Felizardo, Elisabete Dias
doaj +1 more source
In vivodosimetry: trends and prospects for brachytherapy [PDF]
The error types during brachytherapy (BT) treatments and their occurrence rates are not well known. The limited knowledge is partly attributed to the lack of independent verification systems of the treatment progression in the clinical workflow routine.
Kertzscher, G +4 more
openaire +4 more sources
Potential of Nanoparticle‐Based Phototherapies for Future Treatment of Uveal Melanoma
This review evaluates nanoparticle‐based phototherapies for uveal melanoma, highlighting emerging strategies to enhance tumor targeting, light delivery, and treatment precision. Preclinical data indicate improved efficacy and reduced toxicity, supporting their potential to enhance localized treatment and future translational advances. (Generated by the
Emilie Lambert +8 more
wiley +1 more source
Background Huntington’s disease (HD) is a rare neurodegenerative disorder caused by an expansion of the CAG trinucleotide repeat in the huntingtin gene which encodes the mutant huntingtin protein (mHTT) that is associated with HD-related ...
Jordy Akkermans +10 more
doaj +1 more source
A Validation Method for EPID In Vivo Dosimetry Algorithms
The aim of this study was to develop and apply an evaluation method for assessing the accuracy of a novel 3D EPID back-projection algorithm for in vivo dosimetry. The novel algorithm of Dosimetry Check (DC) 5.8 was evaluated. A slab phantom homogeneously
Marco Esposito +5 more
doaj +1 more source
A novel hetero‐bivalent agent, 68Ga/177Lu‐FZ‐NF‐1, concurrently targets Nectin‐4 and FAP in triple‐negative breast cancer. It yields significant preclinical tumor regression and clinically identifies additional metastatic lesions missed by 18F‐FDG PET, demonstrating promising theranostic potential for personalized management.
Ye Li +13 more
wiley +1 more source