Results 51 to 60 of about 137,416,107 (153)
Incorporating Clinical Imaging into the Delivery of Microbeam Radiation Therapy
Synchrotron microbeam radiation therapy is a promising pre-clinical radiation treatment modality; however, it comes with many technical challenges. This study describes the image guidance protocol used for Australia’s first long-term pre-clinical MRT ...
Jason Paino +11 more
doaj +1 more source
The study integrates density functional theory with radiochemical and biological validation to compare DOTA‐, PSC‐, and DOTAM‐based chelator‐conjugates for 203Pb/212Pb theranostic applications. Distinct differences in metal coordination, electrostatic properties, conformational flexibility, cellular uptake, biodistribution, and dosimetry are identified
Jeongyun Kim +12 more
wiley +1 more source
Background: The use of electronic portal imaging devices (EPIDs) is a method for the dosimetric verification of radiotherapy plans, both pretreatment and in vivo.
Ali Jomehzadeh +3 more
doaj +1 more source
An electronics‐free, self‐powered Wearable Disposable Electrotherapy (WDE) patch delivers a controlled electrotherapy dose through intact skin surrounding the wound, without electronics. In a rat full‐thickness wound model, WDE accelerates wound closure and promotes tissue regeneration, including collagen deposition, angiogenesis, re‐epithelialization,
Mojtaba Belali Koochesfahani +11 more
wiley +1 more source
In Vivo Dosimetry for External Photon Treatments of Head and Neck Cancers by Diodes and TLDs
[[abstract]]©2004 OXFORDJOURNALS - In vivo dosimetry was implemented for treatments of head and neck cancers in the large fields. Diode and thermoluminescence dosemeter (TILD) measurements were carried out for the linear accelerators of 6 MV photon beams.
Tung CJ;Wang HC;Lo SH;Wu JM;Wang CJ +1 more
core +1 more source
External beam radiotherapy with photon beams is a highly accurate treatment modality, but requires extensive quality assurance programs to confirm that radiation therapy will be or was administered appropriately.
Igor Olaciregui-Ruiz +7 more
doaj +1 more source
This paper describes a new real-time, in vivo, noninvasive, biasless detector system acting as a beam monitoring and relative dose measurement system.
G A Pablo Cirrone +12 more
doaj +1 more source
Multilevel mechanisms of iTBS in CNS diseases and clinical translation. iTBS engages coordinated synaptic, glial, neurovascular, subcellular, and network‐level mechanisms. This Graphical Abstract summarizes shared and disease‐specific adaptations across stroke, spinal cord injury, Alzheimer's disease, Parkinson's disease, and depression, proposing a ...
Jingkai Tang +11 more
wiley +1 more source
The efficacy and toxicity of radionuclide therapy are believed to be directly related to the radiation doses received by target tissues; however, nuclear medicine therapy continues to be based primarily on the administration of empirical activities to ...
Marcelo Tatit Sapienza +1 more
doaj +1 more source
Background and purpose: In magnetic resonance guided online adaptive radiotherapy, the patient model used for plan adaptation and dose calculation is created online under stringent time constraints.
Begoña Vivas Maiques +3 more
doaj +1 more source

