Results 361 to 370 of about 6,115,741 (434)

Impact of bulk density assignment of bone on MRI‐based abdominal region radiotherapy planning for MR‐linac workflow

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose The purpose of the present study was to evaluate the impact of bone relative electron density (rED) assignment on radiotherapy planning for the abdominal region. Methods Twenty patients who received abdominal radiotherapy using MR‐Linac and underwent magnetic resonance imaging (MRI) and computed tomography (CT) simulation were analyzed.
Kota Abe   +4 more
wiley   +1 more source

Practical experience in commissioning ring applicators using ring applicator component type with bravos control software v1.2

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose The Bravos v1.2 control software introduces a ring applicator component type (ACT) with channel length verification to address geometric characteristics and dosimetric discrepancies caused by source positioning inaccuracies. This study aims to commission the ring applicator and investigate the new ring ACT in Bravos 1.2.
Xiuxiu He   +4 more
wiley   +1 more source

Quantification and dosimetric impact of intra‐fractional bladder changes during CBCT‐guided online adaptive radiotherapy for pelvic cancer treatments

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose This study quantitatively evaluates bladder changes and their dosimetric impact during the on‐couch adaptive process on a commercial CBCT‐based online adaptive radiotherapy (CT‐gART) platform. Methods Data from 183 fractions of ten patients receiving online ART for pelvic cancers were analyzed retrospectively.
Ingrid Valencia Lozano   +7 more
wiley   +1 more source

Position‐dependent offset corrections for ring applicator reconstruction in cervical cancer brachytherapy

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Due to the tight curvature in their design, ring applicators are usually associated with large positioning errors. The standard practice to correct for these deviations based on global offsets may not be sufficient to comply with the recommended tolerance.
Leon G. Aldrovandi   +3 more
wiley   +1 more source

A Python package for fast GPU‐based proton pencil beam dose calculation

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Open‐source GPU‐based Monte Carlo (MC) proton dose calculation algorithms provide high speed and unparalleled accuracy but can be complex to integrate with new applications and remain slower than GPU‐based pencil beam (PB) methods, which sacrifice some physical accuracy for sub‐second plan calculation.
Mahasweta Bhattacharya   +4 more
wiley   +1 more source

Risk analysis of the Unity 1.5T MR‐Linac adapt‐to‐shape workflow

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background and Purpose The adapt‐to‐shape (ATS) workflow on the Unity MR‐Linac (Elekta AB, Stockholm, Sweden) allows for full replanning including recontouring and reoptimization5. Additional complexity to this workflow is added when the adaptation involves the use of MIM Maestro (MIM Software, Cleveland, OH) software in conjunction with ...
Jiayi Liang   +13 more
wiley   +1 more source

JACMP 2005–2009

open access: yes
Journal of Applied Clinical Medical Physics, EarlyView.
Timothy D. Solberg
wiley   +1 more source

Home - About - Disclaimer - Privacy