Results 241 to 250 of about 46,142 (281)
Some of the next articles are maybe not open access.

Fluorescent Indicator Displacement Assay for Ligand−RNA Interactions

Journal of the American Chemical Society, 2010
Since the discovery of the RNA functions modulating gene expression, functional RNA has become an attractive drug target. Ligand-RNA interactions have been studied by covalent labeling of either the ligand or RNA with fluorescent dyes or immobilization on the sensing devices. However, it is desirable to investigate the interactions without any chemical
Jinhua, Zhang   +2 more
openaire   +2 more sources

Indicator displacement assay for freshness monitoring of green tea during storage

Food Research International, 2023
Aging of green tea leads to reductions in its flavor and health value, yet in situ testing methods for green tea freshness are lacking. A novel sensitive indicator displacement assay (IDA) sensor was constructed and applied for monitoring of green tea freshness during storage.
Yiyi, Zhang   +4 more
openaire   +2 more sources

Carbohydrate sensing with a metal-based indicator displacement assay

Chemical Communications, 2011
A Pd-based indicator displacement assay for the fluorimetric sensing of carbohydrates has been developed. The assay allows the detection of saccharides in the low millimolar concentration range in water at neutral pH.
Vera, Janowski, Kay, Severin
openaire   +2 more sources

Allosteric Indicator Displacement Enzyme Assay for a Cyanogenic Glycoside

Chemistry – A European Journal, 2013
AbstractIndicator displacement assays (IDAs) represent an elegant approach in supramolecular analytical chemistry. Herein, we report a chemical biosensor for the selective detection of the cyanogenic glycoside amygdalin in aqueous solution. The hybrid sensor consists of the enzyme β‐glucosidase and a boronic acid appended viologen together with a ...
Jose, D. Amilan   +2 more
openaire   +2 more sources

An indicator displacement assay recognizes enantiomers of chiral carboxylates

Chemical Communications, 2019
Analyte chirality induces changes in fluorescence.
Sara Sheykhi   +3 more
openaire   +2 more sources

Molecular recognition and indicator-displacement assays for phosphoesters

Tetrahedron, 2004
Abstract The binding affinities of host 1 towards different phosphoesters were studied. An indicator-displacement assay was also performed, which was able to detect the host–guest interactions with a small visual color change. The degree of substitutions of the phosphate, the functionality of the substituents, and the steric bulk of the ...
Tianzhi Zhang, Eric V. Anslyn
openaire   +1 more source

Cucurbituril-mediated AIE: An unconventional indicator displacement assay for ketamine detection

Dyes and Pigments, 2022
Abstract Typical AIE luminogens with extensive π-electron conjugation are limited in use on account of their complex synthesis, high cost and environmental concerns. To this end, we report here a novel host-guest inclusion complex that is assembled from nonemissive ligands, and surprisingly exhibits notable AIE features in aqueous solution while ...
Kun Yan   +8 more
openaire   +1 more source

Fluorescent indicator displacement assay of ligands targeting 10 microRNA precursors

Bioorganic & Medicinal Chemistry, 2013
Fluorescent indicator displacement (FID) assay is a rapid and convenient assay for identifying new ligands that bind to the target molecules. In our previous studies, we have shown that a series of 2,7-diaminoalkoxy xanthone and thioxanthone derivatives can be used as fluorescent indicators for detecting the interaction between RNA and a ligand.
Asako, Murata   +3 more
openaire   +2 more sources

Colorimetric enantiodiscrimination of mandelic acid by indicator displacement assay

Chinese Chemical Letters, 2015
Abstract The colorimetric enantiodiscrimination between mandelic acid and l -proline-Cu (II) is exploited to develop enantioselective indicator displacement assays. The sensitivity of the assay could be tuned by using a colorimetric indicator. The chromophoric ligand, pyrocatechol violet, effectively competes with the mandelic acid guest for open ...
Xue-Xian Chen, Li-Ming Yuan
openaire   +1 more source

A new strategy for calibrating indicator displacement assay (IDA)-based sensor systems

Analytica Chimica Acta, 2020
A novel strategy for calibrating Indicator Displacement Assay (IDA)-based sensors is presented herein. The main idea is to replace the instrumental measurement responses by the equilibrium concentration of spectroscopically active species which can be obtained by the Classical Least Squares (CLS) method. Also, coupling the Indirect Hard Modelling (IHM)
Somaiyeh Khodadadi, Karimvand   +1 more
openaire   +2 more sources

Home - About - Disclaimer - Privacy