Results 231 to 240 of about 26,844 (306)

Design and Experimental Study of Pressure Maintenance and Temperature Control System for Hydrate Pressure Core Processing Device

open access: yesEnergy Science &Engineering, EarlyView.
This paper presents a hydrate pressure core processing device integrated with a high‐precision active control system to perform nondestructive transfer, cutting, and analysis. To address the limitations of slow dynamic response and high thermal inertia in traditional passive systems, a differentiated control scheme is implemented.
Liwen Nan   +3 more
wiley   +1 more source

Few-Shot Learning in Wi-Fi-Based Indoor Positioning. [PDF]

open access: yesBiomimetics (Basel)
Xie F, Lam SH, Xie M, Wang C.
europepmc   +1 more source

Comparative Performance Analysis of Various Flat Plate Solar Collectors Incorporating Spiral and Square Arrangement of Circular Type Riser Tube

open access: yesEnergy Science &Engineering, EarlyView.
Three flat‐plate collectors with spiral and square coiled riser tubes were tested and it was found that the spiral type provides the best results with a thermal efficiency of 66.98% for a mass flow rate of 0.4 kg/min. Riser tube geometry is a key factor in optimizing flat‐plate collector output.
Sakhail Islam Biaz   +4 more
wiley   +1 more source

Temperature Coefficient Analysis of Polycrystalline PV Modules Under Field Conditions in Ghana

open access: yesEnergy Science &Engineering, EarlyView.
Field measurements from a commercial PV plant in Ghana show polycrystalline module temperature coefficients of −0.473%/°C—31% higher than manufacturer values—highlighting the risk of underestimating energy losses and degradation in fast‐growing West African solar deployments.
Emmanuel Akono Sarsah   +1 more
wiley   +1 more source

Lacrimal caruncula thermography overestimates rectal temperature in horses: Influence of camera type and measurement distance

open access: yesEquine Veterinary Journal, EarlyView.
Abstract Background Rectal temperature (RT) is the gold standard for assessing body temperature in horses, but handling and welfare concerns limit its use. Thermography of the lacrimal caruncula (LC) has been proposed as a noncontact alternative, although its accuracy may be influenced by device characteristics and measurement distance.
Ömer Tarık Orhun   +4 more
wiley   +1 more source

Finalisation of the European Approach to Assess the Fire Performance of Facades—Brief Information on the Outcome of the Project

open access: yesFire and Materials, EarlyView.
ABSTRACT This research was conducted within the framework of project SI2.825082, funded by the European Commission—DG GROW. The project's objective was to finalise a European approach for assessing the fire performance of façades under medium and large fire exposure conditions.