Results 51 to 60 of about 162,004 (308)

Optimal passive filter design for effective utilization of cables and transformers under non-sinusoidal conditions [PDF]

open access: yes, 2014
Transformers and cables have overheating and reduced loading capabilities under non-sinusoidal conditions due to the fact that their losses increases with not only rms value but also frequency of the load current.
Aleem, SHEA   +3 more
core   +1 more source

Investigation of a Resonant dc–dc Converter for Light Rail Transportation Applications

open access: yesEnergies, 2018
A high efficiency dc–dc converter is studied for light rail transportation applications on DC microgrid systems. The adopted structure includes two series-connected resonant circuits with single isolated transformer from input 750 V to output 48 V.
Bor-Ren Lin
doaj   +1 more source

LCDEiT: A Linear Complexity Data-Efficient Image Transformer for MRI Brain Tumor Classification

open access: yesIEEE Access, 2023
Current deep learning-assisted brain tumor classification models sustain inductive bias and parameter dependency problems for extracting texture-based image information.
Gazi Jannatul Ferdous   +4 more
doaj   +1 more source

7.2 kV Three-Port SiC Single-Stage Current-Source Solid-State Transformer With 90 kV Lightning Protection

open access: yesIEEE transactions on power electronics, 2022
This article proposes a multiport modular single-stage current-source solid-state transformer (SST) for applications like photovoltaic, energy storage integration, electric vehicle fast charging, data center, etc.
Liran Zheng   +6 more
semanticscholar   +1 more source

The Calibration of Current Transformers by Means of Mutual Inductances [PDF]

open access: yesTransactions of the American Institute of Electrical Engineers, 1915
Reasons are given for the selection of mutual inductances as a means for calibrating current transformers, the most important of which is the wide use to which they may be put besides the calibration of current transformers. The design and manufacture of the apparatus are described, reasons being given for the choice of the form of the secondary coil ...
openaire   +1 more source

Power supply Patent [PDF]

open access: yes, 1968
Power supply with automatic power factor conversion ...
Kramer, M., Martinage, L. H.
core   +1 more source

A practical approach for magnetic core-loss characterization [PDF]

open access: yes, 1995
A practical approach for magnetic core-loss characterization up to a few megahertz is presented. An error analysis is for the first time performed, revealing that corrections are needed to compensate for errors introduced by the extra phase shift ...
Tan, F. Dong   +2 more
core   +1 more source

Characterization of a Recyclate‐Based MgO‐Steel Composite As‐Sintered Inert Anode Candidate After Exposure to Cryolite Electrolysis

open access: yesAdvanced Engineering Materials, EarlyView.
Carbon‐free inert anodes are essential for decarbonizing aluminum electrolysis. This study investigates a recyclate‐based MgO‐316L steel composite anode tested under galvanostatic Hall–Héroult conditions in cryolite at 1000°C. Microstructural analysis reveals selective MgO fluorination, spinel and oxide layer formation, electrolyte infiltration, and ...
Serhii Yaroshevskyi   +7 more
wiley   +1 more source

A pulse generator with inductive energy storage for measuring the grounding resistance of transmission line towers

open access: yesVestnik MGTU, 2018
The pulse method may be used to measure the footing resistance of transmission towers with overhead grounding wires. Measuring systems that obtain the time dependent transient impedance may be used to measure the low-frequency resistance of transmission ...
Kolobov V. V.   +2 more
doaj   +1 more source

Corrosion and Process Analysis of a Preoxidized MgO Recyclate‐Based Cermet Anode in Laboratory‐Scale Na‐Cryolite Molten Salt Electrolysis of Aluminum at 1000°C

open access: yesAdvanced Engineering Materials, EarlyView.
EDX elemental map of the pre‐oxidized MgO–steel cermet anode cross section after electrolysis. The development of inert anodes for aluminum electrolysis remains challenging due to the high corrosivity of cryolite‐based melts at 950°C–1000°C. This study investigates the corrosion and process behavior of a carbon‐free MgO–steel cermet anode derived from ...
Alexander Adamczyk   +7 more
wiley   +1 more source