Results 71 to 80 of about 16,181 (259)
Introduction Inertial measurement units have been proposed for automated pose estimation and exercise monitoring in clinical settings. However, many existing methods assume an extensive calibration procedure, which may not be realizable in clinical ...
Rezvan Kianifar +4 more
doaj +1 more source
Characterization And Calibration Of Mems Inertial Measurement Units
Publication in the conference proceedings of EUSIPCO, Lausanne, Switzerland ...
Gokcen Aslan, Afsar Saranli
openaire +3 more sources
A systematic review is conducted to assess the influence of electrode architecture across micro‐ to mesoscopic length scales on electron‐transfer pathways in electrocatalysis. We discuss the structure‐activity relationships in electrocatalytic applications, including resource recovery and environmental remediation, and provide cost‐effective, efficient
Manshu Zhao +6 more
wiley +1 more source
A new class of sulfur‐free, oxygen‐bridged dibenzofuran‐based polymers is developed for ultrahigh‐refractive‐index applications. The rigid π‐extended architecture and enhanced molecular polarizability enable exceptional optical performance, combining refractive indices up to 1.848 with high Abbe numbers and full visible transparency. This work offers a
Hend A. Hegazy +5 more
wiley +1 more source
Postural Stability Analysis with Inertial Measurement Units in Alzheimer's Disease
Background: The cause of frequent falls in patients with Alzheimer's disease (AD) is still not well understood. Nevertheless, balance control and sensory organization are known to be critical for moving safely and adapting to the environment. Methods: We
Miguel F. Gago +6 more
doaj +1 more source
Tailored Diketopyrrolopyrrole Derivatives for Efficient Deep‐Red Organic Lasers
Tailored diketopyrrolopyrrole derivatives exhibit high stable amplified spontaneous emission with single or dual bands. Incorporated into distributed‐feedback lasers based on one‐ and two‐dimensional dichromated‐gelatin diffractive gratings, these materials provide a robust, flexible platform for integrated organic deep‐red light sources. ABSTRACT Deep‐
Pablo Pasqués‐Gramage +10 more
wiley +1 more source
Foot-Mounted Inertial Measurement Units-Based Device for Ankle Rehabilitation
Ankle sprains are frequent injuries that occur among people of all ages. Ankle sprains constitute approximately 15% of all sports injuries, and are the most common traumatic emergencies.
Alfonso Gómez-Espinosa +2 more
doaj +1 more source
Engineered red blood cell‐derived extracellular vesicles (eRBCEVs) are synthesized via controlled microfluidic assembly from native RBC lipids, enabling tunable encapsulation of proteins, nucleic acids, nanoparticles, and viral vectors. The platform demonstrates reproducible nanoscale architecture, preserved membrane composition, and functional cargo ...
Chiranth K. Nagaraj +23 more
wiley +1 more source
Selection of basic elements for a two-axis multisensor inertial sensor
The paper proposes a basic scheme for constructing a two-axis multisensor inertial sensor (MIS), which allows simultaneous measurement of translational linear acceleration and angular velocity along two axes in the coordinate system associated with an ...
N. A. Mukhoed
doaj
Monitoring workers’ safety compliance is critical to construction accident prevention. However, most of the previous research focuses on checking the entry of workers wearing safety belts and the monitoring of the fastening action of safety rope screw ...
Zixin Han, Yaowu Wang
doaj +1 more source

