Results 111 to 120 of about 77,481 (264)
Impact of Carina Width on Re‐Ablation Rate of Atrial Fibrillation After Primary Cryoballoon‐Ablation
Right side carina width is associated with the incidence of reconnection of RPVs and re‐ablation. Increased left side carina width was associated with re‐ablation rate, but there was no association with reconnection of the LPVs. ABSTRACT Background Reconnection of the pulmonary veins (PVs) is the primary cause of atrial fibrillation (AF) episodes after
Miriam Müller +3 more
wiley +1 more source
At the eighth week of human embryonic development, 3D transparent imaging enables clear visualization of the outflow tract's morphological features, revealing its anatomical components in detail. Abstract The ductus arteriosus (DA) is a critical fetal vascular structure that shunts blood from the pulmonary artery to the aorta, bypassing the non ...
Conghong Xu +7 more
wiley +1 more source
ABSTRACT Aim Children with chronic liver disease and portosystemic circulation disorders may have long‐term neurocognitive problems. Hypermanganesemia, reported in this group, could be a contributor. This systematic review aimed to characterise liver and portosystemic circulation disorders associated with hypermanganesemia and reported neurocognitive ...
Helena J. Kim +6 more
wiley +1 more source
Aneurysm of the inferior vena cava [PDF]
Suresh, Kalkunte R. +3 more
openaire +2 more sources
ABSTRACT Background Leadless pacemakers (LPMs) have been shown to reduce complications compared with conventional transvenous pacing. Transfemoral venous access (FA) is the standard implantation approach; however, the transjugular approach (JA) has recently emerged as an alternative strategy, but comparative evidence remains limited.
Federico Giannino +11 more
wiley +1 more source
ABSTRACT Helix‐fixed leadless pacemaker delivery can be challenging after tricuspid annuloplasty with a rigid ring. An 80‐year‐old woman with prior mitral valve repair, tricuspid annuloplasty (26‐mm MC ring), and Maze III surgery presented with syncope due to atrial fibrillation with a slow ventricular response. Standard maneuvers failed to advance the
Yuya Nakamura +5 more
wiley +1 more source
RESUMEN Los tumores renales malignos con trombos tumorales que involucran a la vena cava inferior y a la aurícula derecha son raros. Presentamos un caso operado exitosamente de un hipernefroma renal, con trombosis tumoral de vena cava inferior Grado
Alexei Suárez Rivero +6 more
doaj
Graphical Abstract ABSTRACT Fluoroscopy has traditionally been the mainstay imaging technique for guidance during electrophysiology (EP) ablation procedures. The numerous disadvantages associated with radiation exposure for both operators and patients have created the need for zero‐fluoroscopy (ZF) approaches. Today, electrophysiologists have access to
Dimitrios Kotzadamis +6 more
wiley +1 more source
ABSTRACT Introduction Transvenous pacemakers are effective but carry significant short‐ and long‐term complications. Leadless pacemakers were developed to overcome these limitations, however, data in high‐risk patients ineligible for transvenous systems remain limited.
Moshe Katz +7 more
wiley +1 more source

