Strengthening of Infill Masonry Walls with FRP Materials

Journal of Composites for Construction, 2011
This paper evaluates the effectiveness of different externally bonded glass fiber–reinforced polymer (GFRP) systems for increasing the out-of-plane resistance of infill masonry walls to loading. The research included a comprehensive experimental program comprising 14 full-scale specimens, including four unstrengthened (control) specimens and 10 ...
Dillon S. Lunn, Sami H. Rizkalla
openaire   +1 more source

Strengthening masonry infill walls with reinforced plaster

Proceedings of the Institution of Civil Engineers - Structures and Buildings, 2010
One technique for strengthening masonry infill walls against seismic lateral forces permitted by the Turkish Seismic Code is to add a plaster layer with mesh reinforcement to one face of the wall. The study described in this paper was performed to test and analyse the effectiveness of this technique for lateral loads.
Altin, SİNAN   +3 more
openaire   +2 more sources

RC-frames infilled with rc infill-walls for seismic retrofitting

2021
The seismic retrofitting of existing multi-storey multi-bay reinforced concrete (RC) frame buildings by the conversion of selected bays into new RC infilled walls is the subject of this research work. The parametric study of the contribution of dowels that connect a new RC infill wall to the surrounding RC frame members was performed through nonlinear ...
openaire   +1 more source

Analysis Model for Concrete Infill Slit-Wall

2009
This paper discussed analytic models of frame-slit-wall system suggested by JGJ99-98 and pointed out the necessity of considering shear deformation of web of steel beams when determining the section of equivalent cross bracing or shear plate. The models suggested by JGJ99-98 cannot predict the actual shear forces in steel girders, its bending ...
Xufeng Mi, Lin Wang, Guobao Zhou
openaire   +1 more source

Experimental Response of a Precast Infill Wall System

2003
Many reinforced concrete moment resisting frame buildings in seismic zones lack strength and ductility. A precast infill system may provide an economic advantage for the retrofit of these structures. In order to evaluate the performance of this type of system, a two-story nonductile frame was constructed and rehabilitated with a precast infill wall and
Robert J. Frosch   +2 more
openaire   +1 more source

Tests on infill sheeting of Combi-Wall

1987
Civil Engineering and ...
Bouwman, L.P. (author)   +1 more
openaire   +1 more source

Importance of masonry infill walls for framed buildings

2017 International Conference on ENERGY and ENVIRONMENT (CIEM), 2017
The paper presents a study about the effect of masonry infill walls on the behavior of framed buildings, in seismic areas. The study was done for a building that will be built in Bucharest, Romania. In this case, the building will have 6 stories. The bays are narrow, because of the architecture requirements. The structure is composed of concrete frames.
openaire   +1 more source

Isolation of infill walls as solution for both masonry infills and RC structures

2023
Marinkovic, Marko   +3 more
openaire   +1 more source

SHCC precast infill walls for seismic retrofitting

2009
Structures must resist lateral force as earthquake without collapse and significant damage to the structural members. On the seismic design, the Korean Building Code requires that the structures should obtain satisfactory design load and seismic reinforcement detail so that adequate ductile response and limiting condition for maximum displacement ...
openaire   +1 more source