Results 91 to 100 of about 10,677,552 (246)
Protection of power transformer using microcontroller-based relay [PDF]
This paper describes the design and implementation of the micro controller-based system for protecting power transformer. The system includes facilities for discrimination between internal fault current and magnetizing inrush current, differential ...
Bashi, Senan Mahmood +4 more
core +1 more source
Ferromagnetically Shielded Fault Current Limiter (FS‐FCL) Evaluation in Power Line
This study introduces a new ferromagnetically shielded FS‐FCL design and its control strategy for limiting and interrupting fault currents. The fully shielded core structure enhances inductance and prevents saturation, enabling an immediate fault response without causing voltage drop during normal conditions.
Kamran Ghorbanyan, Selim Acar
wiley +1 more source
Modeling and Simulation of a Distributed Power System for Avionic Application [PDF]
This paper describes design and analysis method for a DC distributed power system for Avionic Application utilizing simulation. In order to obtain rapid time to market, the used system components are typically commercial off-the-shelf components (COTS ...
Alou Cervera, Pedro +5 more
core +1 more source
This paper reviews the common grid‐following (GFL) and grid‐forming (GFM) control principles, technical characteristics, and the limitations of their medium‐voltage direct current (MVDC) applications. In addition, typical switching strategies for GFL and GFM are introduced and analysed. Finally, the applications of MVDC adopting GFL, MVDC adopting GFM,
Xiaoyang Wang +5 more
wiley +1 more source
Based on using closing resistance to reduce transformer excitation inrush current produced in underloading and no-load, an improved method of in series with capacitor on closing resistance was proposed.
LI Ping, SONG Xiao
doaj
Solid-State Inrush Current Limiter Controller Based on Inrush Prediction for Large Transformers
Inrush current problems of the industrial transformers are occasionally more serious than the utility transformers. A new Solid-State Inrush Current Limiter (SSICL) is proposed for medium voltage power transformers. The SSICL consists of three similar sets.
Tashakor, Nima +4 more
openaire +2 more sources
Transients in no-load condition of power transformer 20/0,4 kV [PDF]
Ovaj rad predstavlja inovativan pristup u analizu prijelaznih pojava u elektroenergetskom sustavu korištenjem novopredloženih načina obrade podataka dobivenih iz procesora ugrađenog u moderne zaštitne releje u elektroenergetskom sustavu.
Damir Crnković +2 more
core +1 more source
This article presents a Fifteen‐level inverter topology that has a lesser number of switches (12) and can accommodate isolated DC sources. The total harmonic elimination (THD) of the proposed topology using genetic algorithm is within the IEEE 519 standards. Further, the fifteen‐level inverter is implemented in Hardware and firing pulses were generated
Yogesh Joshi +4 more
wiley +1 more source
Inrush Current Reduction of Three-Phase Transformers Using Optimal Energization Angle Control
When a transformer is energized, the inrush current can reach several tens of times higher than the steady-state magnetizing current, which may cause maloperation of protective relays, voltage dips and deterioration of power quality.
Jin-Sung Cho +2 more
doaj +1 more source
Application of Park's power components to the differential protection of three-phase transformers [PDF]
This paper presents a new scheme for power transformers differential protection, in which the concept of the Park's instantaneous differential powers is introduced. The proposed method is able to detect winding insulation failures and to distinguish them
A.J. Marques Cardoso +45 more
core +1 more source