An inrush current will be generated inside a converter transformer during no-load switching on or off. The inrush current will cause severe vibration of the winding and other components of the converter transformer.
Jinzhuang Lv +7 more
doaj +1 more source
Three-phase active damping LCL-type grid-connected converters are usually used in distributed power generation systems. However, serious inrush current will be aroused when the grid-connected converter starts, especially in rectifier mode, if no ...
Shiying Zhou +4 more
doaj +1 more source
The Analogia Entis for Reformed Theology: Retrieving Calvin's Implicit Metaphysics
Abstract The famous controversy between Emil Brunner and Karl Barth which led to Barth's ‘No!’ was driven by disagreements over how to read John Calvin: Barth and Brunner never agreed on whether Calvin had a doctrine of the analogy of being. This article rekindles the debate.
Silvianne Aspray
wiley +1 more source
Inrush current with high amplitude is generated when the transformer is energized. On the one hand, it will have a negative impact on the safety of the transformer itself, and even cause the relay protection to malfunction.
Yuanlin Pan +5 more
doaj +1 more source
A Forced Union: Exploring the Consequences of India's Removal of Jammu and Kashmir's Special Status
ABSTRACT This article adds to academic literature interested in two core questions: What happens to residents as a result of an annexation? And how do aggressor states maintain control over an annexed territory where there is a history of insurgency and mobilization for independence?
Serena Hussain
wiley +1 more source
Analyzing kinetics of deformation of boundary rocks of mine workings [PDF]
Purpose is to analyze nature of rock deformation and to estimate experimentally state of mine workings being supported under the conditions of areas disturbed by coal mining. Methods. The studies involved field instrumental observations within measuring
Nehrii, S +3 more
core +1 more source
This review evaluates advanced intelligent fault diagnosis and resilient fault‐tolerant control strategies for modular multilevel converters (MMCs). It highlights how integrating machine learning with robust control architectures enhances reliability and operational continuity, providing a roadmap for developing more resilient, self‐healing power ...
Muhammad Haris Saleem +3 more
wiley +1 more source
Magnetically coupled emission regulator [PDF]
Magnetic coupling between input and power handling circuits isolates high voltage. A feedback regulator samples the ion source bias current and provides deviation signals to a magnetic amplifier pulse modulator.
core +1 more source
Large‐Scale Hydrogen Storage: Surface and Subsurface Challenges
This review examines underground hydrogen storage with emphasis on the interaction between surface facilities and subsurface reservoirs. Variable renewable hydrogen requires compression, buffering, and purification before injection, while subsurface processes influence wellhead pressure, temperature, and composition.
Mostafa Montazeri +3 more
wiley +1 more source
Contribution of inrush current to mechanical failure of power transformers windings
This work presents a study regarding the contribution of inrush current to the occurrence of mechanical fatigue in windings of a power transformer and, consequently, the impact of that phenomenon on the equipment's lifetime. In order to perform the study,
Rafael M.R. Barros +5 more
doaj +1 more source