Results 41 to 50 of about 7,418,041 (222)
This review systematically outlines two‐stage power management circuits for TENGs, integrating AC–DC and DC–DC conversion to overcome high impedance and unstable output. It highlights strategies for efficient energy extraction and stable power delivery, enabling the development of reliable self‐powered systems for safety monitoring and applications in ...
Jiaxin Hu +5 more
wiley +1 more source
Principles of implementation of current protection of elements of electric power systems with power transformers are considered. In some cases, in facilities with power transformers there could be an inrush of a magnetizing current that can cause a false
F. A. Romaniuk, A. G. Shapozhnikova
doaj +1 more source
Inrush current with high amplitude is generated when the transformer is energized. On the one hand, it will have a negative impact on the safety of the transformer itself, and even cause the relay protection to malfunction.
Yuanlin Pan +5 more
doaj +1 more source
As the share of renewable energy in the energy mix continues to increase, the penetration of distributed renewable generation in distribution networks is also rising steadily. Loop‐closing operation provides an effective means to enhance renewable energy accommodation across different grid partitions.
Ningyu Zhang +6 more
wiley +1 more source
An inrush current will be generated inside a converter transformer during no-load switching on or off. The inrush current will cause severe vibration of the winding and other components of the converter transformer.
Jinzhuang Lv +7 more
doaj +1 more source
Three-phase active damping LCL-type grid-connected converters are usually used in distributed power generation systems. However, serious inrush current will be aroused when the grid-connected converter starts, especially in rectifier mode, if no ...
Shiying Zhou +4 more
doaj +1 more source
ABSTRACT The double‐break vacuum circuit breakers (VCBs) that utilize series break technology effectively increase the switching capability for capacitive currents, elevate the withstand voltage level, and reduce the likelihood of restrike, all without compromising the breaking capacity for short‐circuit currents.
Yun Geng +6 more
wiley +1 more source
The Analogia Entis for Reformed Theology: Retrieving Calvin's Implicit Metaphysics
Abstract The famous controversy between Emil Brunner and Karl Barth which led to Barth's ‘No!’ was driven by disagreements over how to read John Calvin: Barth and Brunner never agreed on whether Calvin had a doctrine of the analogy of being. This article rekindles the debate.
Silvianne Aspray
wiley +1 more source
Intelligent Monitoring and Warning for Road‐Network Tunnels Via Feature Matching
To address the safety issues in mountain tunnel construction, an early warning model integrating association rules and text vectorization feature matching was developed. The validation on two tunnels demonstrated that this model can accurately predict accident types and actively identify risks, providing support for dynamic safety management and the ...
Yinghui Zhang, Xianghui Liu
wiley +1 more source
Investigations into the transformer inrush current problem [PDF]
A transformer being energised may draw a large transient current from the grid supply, resulting in a temporary voltage dip at the point of connection (POC) where customers are connected. The voltage dip is dependent upon the magnitude of the transformer
Ekwue, A.O., Rawn, B
core +1 more source

