Time and resources of peripherally inserted central catheter insertion procedures: a comparison between blind insertion/chest X-ray and a real time tip navigation and confirmation system [PDF]
Kenneth J Tomaszewski,1 Nicole Ferko,2 Sarah S Hollmann,2 Simona C Eng,3 Howard M Richard,4 Lynn Rowe,5 Susan Sproule6 1KJT Group, Inc., Honeoye Falls, NY, USA; 2Cornerstone Research Group, Inc., Burlington, ON, Canada; 3Department of Hospitalist ...
Tomaszewski KJ +6 more
doaj +2 more sources
Randomized crossover comparison between the i-gel and the LMA-Unique in anaesthetized, paralysed adults [PDF]
<b>Background</b>: The i-gel differs from other supraglottic airway devices, in that it has a softer, non-inflatable cuff. This study was designed to compare the performance of the i-gel and the LMA-Unique (LMA-U) when used during anaesthesia
J. Kinsella +7 more
core +9 more sources
On dynamic delay and repeater insertion in distributed capacitively coupled interconnects. [PDF]
Repeater insertion is a well established technique to minimise the propagation delay over long resistive interconnects. In deep sub-micron technologies, as the wires are spaced ever closer and signal rise and fall times go into the sub-nanosecond region,
Tenhunen, Hannu, Pamunuwa, Dinesh B.
core +4 more sources
Phenomenology: Exploring Women’s Experiences of First Time IUD Insertion
Purpose: This study aims to explore Indonesian women’s experiences of first-time IUD insertion.Method: This study using phenomenological approach. Three Javanese women who lived in Malang Indonesia were interviewed using an unstructured process and the ...
Fransiska Imavike Fevriasanty +2 more
doaj +1 more source
Timing performance of the silicon PET insert probe [PDF]
Simulation indicates that PET image could be improved by upgrading a conventional ring with a probe placed close to the imaged object. In this paper, timing issues related to a PET probe using high-resistivity silicon as a detector material are addressed.
A, Studen +13 more
openaire +2 more sources
Impact of the Timing of Percutaneous Nephrostomy on the Prognosis of Obstructive Urolithiasis With Sepsis: A Retrospective Cohort Study [PDF]
Purpose The aim of this study was to investigate the prognostic impact of time to percutaneous nephrostomy (PCN) insertion on obstructive ureteral stones with sepsis.
Ji Eun Yu +5 more
doaj +1 more source
On the Estimation of the Insertion Time of LTR Retrotransposable Elements [PDF]
It has been proposed that the insertion time of a long terminal repeat (LTR) retrotransposon can be estimated by the divergence between the two LTRs at the both ends because their sequences were identical at the insertion event. This method is based on the assumption that the two LTRs accumulate point mutations independently; therefore, the divergence ...
T E, Kijima, Hideki, Innan
openaire +2 more sources
Objectives: The present study was conducted to compare digital technique and suction catheter guided technique for Proseal laryngeal mask airway insertion regarding ease of insertion, number of attempts for successful insertion and insertion time in ...
Teena Bansal +2 more
doaj +1 more source
Introduction: The purpose of this study was to clarify how many cases surgeons need to experience to pass the learning phase of robotic-assisted spine surgery using the cumulative sum (CUSUM) analysis. Methods: A retrospective review was conducted on the
Yoshiaki Torii +5 more
doaj +1 more source
On the insertion time of random walk cuckoo hashing [PDF]
Cuckoo Hashing is a hashing scheme invented by pervious study of Pagh and Rodler. It uses d ≥ 2 distinct hash functions to insert n items into the hash table of size m = (1 + ε)n. In their original paper they treated d = 2 and m = (2 + ε)n. It has been an open question for some time as to the expected time for Random Walk Insertion to add items when d &
Alan M. Frieze, Tony Johansson
openaire +4 more sources

