Results 21 to 30 of about 5,287 (159)
Development of a ±660 kV DC transmission line arrester
In order to improve the lightning withstand level of ±660 kV DC transmission line in China, the authors had begun to develop the ±660 kV DC line arrester since 2014, which was developed successfully in 2016.
Shanqiang Gu +6 more
doaj +1 more source
Tower Air-gaps discharge characteristics and insulation coordination for UHV AC double-circuit line
In order to give out inverse V-type insulator tower air-gaps configuration of double-circuit UHV AC power transmission line, different distance air-gaps from high-voltage electrode to tower frame discharge tests of inverse V-string are carried out ...
Huo Feng, Nan Jing, Ye Qiming, Ma Yeming
doaj +1 more source
Insulation coordination for a modular multilevel converter prototype [PDF]
This paper provides a detailed overview of the dielectric design and insulation coordination applied to a medium voltage modular multilevel converter prototype. The complete system has ratings of 0.5 MVA and is designed for connection to a 10kVd c supply with a system voltage of 6.6kV ac .
Christe, Alexandre +2 more
openaire +1 more source
Integration of the renewable energy sources with utility grids is receiving more impressive concerns to provide extra-green energy sources to work in parallel or to phase out the sources with fossil fuels. The effects of the transient surges are the most
Samy M. Ghania, Anas M. Hashmi
doaj +1 more source
Analysis of Transient Behavior of Mixed High Voltage DC Transmission Line Under Lightning Strikes
Growing urbanization coupled with increased power demands have led to increasing use of mixed power transmission lines with sections of overhead lines (OHL) and underground cables.
Mansoor Asif +4 more
doaj +1 more source
Assessment of Dielectric Strength for 3D Printed Solid Materials in Terms of Insulation Coordination
Insulating materials can be classified into solid, liquid, and gaseous forms. Solid insulation materials are divided into different types such as organic, inorganic, and polymer types. In electrical circuits, solid insulation materials are generally used
Cihat Cagdas Uydur
doaj +1 more source
Many geographical constraints and aesthetic concerns necessitate the partial use of cable sections in the High Voltage DC (HVDC) transmission line, resulting in a mixed transmission line.
Mansoor Asif +4 more
doaj +1 more source
Estimation of New Weighted Controlled Switching Overvoltage by RBFN Model [PDF]
Mitigating switching overvoltages (SOVs) and conducting well-suited insulation coordination for handling stresses are very important in UHV transmission Lines. The best strategy in the absence of arresters is controlled switching (CS). Although elaborate
M. Hasanpour +2 more
doaj +1 more source
A substation is one of the essential aspects of an electrically interconnected system, especially in a grid utility. Power generation, transmission, and distribution systems always need a continuous power supply to the customer.
Bagus Irawan Saputra +2 more
doaj +1 more source
Research on High-voltage System and Test Standards of Railway Vehicles
The differences between international standards and national standards related to high-voltage system for railway vehicles were analyzed and summarized.
Haibo ZHAO +3 more
doaj

