Results 41 to 50 of about 5,287 (159)

Study on overvoltage characteristics and arrester configuration strategy for ±1 100 kV HVDC transmission lines

open access: yesThe Journal of Engineering, 2018
Overvoltage caused by faults or switching is one of the decisive factors affecting the insulation level of equipment in UHVDC transmission systems.
Xiaoguang Zhu   +6 more
doaj   +1 more source

Evaluating Thermal Insulation Strategies for High-Rise Residential Buildings in Sarajevo

open access: yesEnergies
Aging residential buildings in urban areas require effective thermal insulation to enhance energy efficiency and indoor comfort. In Bosnia and Herzegovina (BiH), expanded polystyrene (EPS) is the most commonly used insulation material due to its ...
Florian Teichmann   +7 more
doaj   +1 more source

Impact of Transformer Grounding On TRV During Inductive Load Switching at Transmission and Substation Service Unit (ULTG) Maros

open access: yesJurnal Nasional Teknik Elektro
This paper investigates the impact of transformer grounding configurations on Transient Recovery Voltage (TRV) during fault current interruption in high-voltage power systems. The study evaluates three grounding schemes: Solid–Solid, Solid–Floating, and
Muhammad Khaidir   +5 more
doaj   +1 more source

Reversible dielectric polymers with switchable conduction and insulation for electrostatic protection

open access: yesNature Communications
The pursuit of power density and integration in advanced electronic devices poses a risk of electrostatic discharge to traditional packaging materials. Albeit optimizing the insulation performance of packaging materials seems to be an effective strategy,
Huasong Xu   +16 more
doaj   +1 more source

Breakdown Characteristics of Unequal Sphere–Sphere Electrode Configuration Under DC Stress

open access: yesEngineering Proceedings
Failure of air gap insulation is one of the prominent issues in insulation coordination for outdoor applications. Though uniform electric field distribution is desirable, the difficulty in achieving it often makes insulation engineers settle for weakly ...
Indhulekha Jayachandran   +1 more
doaj   +1 more source

Ambient-Dried Silica Xerogels with Enhanced Strength and Thermal Insulation via Calcium Ion-Glycerol Synergistic Crosslinking

open access: yesGels
Despite their high porosity and wide applicability, silica xerogels face mechanical strength limitations for high-performance applications. This study presents an ambient-pressure sol-gel strategy utilizing calcium-glycerol synergy to produce robust ...
Xiaoyu Xie   +8 more
doaj   +1 more source

Experimental study on flashover voltage characteristics of different arresters at high altitudes and construction of correction models

open access: yesAIP Advances
The unique atmospheric conditions in high-altitude regions significantly affect the external insulation performance of electrical equipment, and existing altitude correction methods struggle to accurately reflect the flashover characteristics of ...
Zhilin Su   +3 more
doaj   +1 more source

Modernizing Outdoor Substation Design by the Novel Application of Probabilistic Design Principles

open access: yesIEEE Access
This paper proposes a structured design methodology for Air Insulated Switchgear (AIS) substations with nominal voltages exceeding 45 kV, specifically for configurations employing stranded flexible conductors.
Abraham Johannes Smit Groenewald   +1 more
doaj   +1 more source

Management of Zero-Sequence Parameters for Earth Faults on the Power Receiver’s Side in IT-Type Networks

open access: yesEnergies
This study examines the behavior and control of zero-sequence parameters in IT-type electrical networks under conditions of capacitive insulation asymmetry and complex asymmetric faults on the power receiver side.
Gennadiy Pivnyak   +5 more
doaj   +1 more source

A New Model of Trapped Charge Sources in Switching Transient Studies in the Presence of Shunt Reactors

open access: yesIEEE Access
Insulation coordination studies are of great importance in power grid reliability. In this paper, a new method is proposed for modeling trapped charge sources (TCS) in switching transient studies.
Mohsen Akafi-Mobarakeh   +4 more
doaj   +1 more source

Home - About - Disclaimer - Privacy