Results 51 to 60 of about 54,547 (303)

Assessment of Overvoltage and Insulation Coordination in Mixed HVDC Transmission Lines Exposed to Lightning Strikes

open access: yesEnergies, 2019
Many geographical constraints and aesthetic concerns necessitate the partial use of cable sections in the High Voltage DC (HVDC) transmission line, resulting in a mixed transmission line.
Mansoor Asif   +4 more
doaj   +1 more source

Advancing Electronic Application of Coordination Solids: Enhancing Electron Transport and Device Integration via Surface‐Mounted MOFs (SURMOFs)

open access: yesAdvanced Functional Materials, EarlyView.
The layer‐by‐layer (LbL) assembly of coordination solids, enabled by the surface‐mounted metal‐organic framework (SURMOF) platform, is on the cusp of generating the organic counterpart of the epitaxy of inorganics. The programmable and sequential SURMOF protocol, optimized by machine learning (ML), is suited for accessing high‐quality thin films of ...
Zhengtao Xu   +2 more
wiley   +1 more source

Research on High-voltage System and Test Standards of Railway Vehicles

open access: yes机车电传动, 2020
The differences between international standards and national standards related to high-voltage system for railway vehicles were analyzed and summarized.
Haibo ZHAO   +3 more
doaj  

NanoMOF‐Based Multilevel Anti‐Counterfeiting by a Combination of Visible and Invisible Photoluminescence and Conductivity

open access: yesAdvanced Functional Materials, EarlyView.
This study presents novel anti‐counterfeiting tags with multilevel security features that utilize additional disguise features. They combine luminescent nanosized Ln‐MOFs with conductive polymers to multifunctional mixed‐matrix membranes and powder composites. The materials exhibit visible/NIR emission and matrix‐based conductivity even as black bodies.
Moritz Maxeiner   +9 more
wiley   +1 more source

Study on the impact of AC system operating frequency elevation on overvoltage characteristics and equipment insulation levels of converter stations

open access: yesZhejiang dianli
The economic advantages of medium-frequency AC collection and flexible DC transmission make it a key choice for deep-sea wind power development, where overvoltage and insulation coordination emerge as critical technical bottlenecks.
YE Wenyao   +6 more
doaj   +1 more source

Highly Sensitive Electrochemical Biosensor Based on Hairy Particles with Controllable High Enzyme Loading and Activity

open access: yesAdvanced Functional Materials, EarlyView.
For the first time, a highly sensitive electrochemical biosensor based on SiO2‐based hairy particles with a grafted PDMAEMA polymer brush containing a quantifiable and large amount of immobilized Laccase is reported. The fabricated biosensor exhibits a sensitivity of 0.14 A·m⁻¹, a limit of detection (LOD) of 0.1 µm, and a detection range of 0.3–750 µm,
Pavel Milkin   +7 more
wiley   +1 more source

Research, Creative Works, and Commercialization at UAA FY15 through FY16 YTD. [PDF]

open access: yes, 2016
The UAA Research and Commercialization trend is upward. UAA is experiencing significant growth in research, creative works, and commercialization. We are pursuing a strategic approach to fostering, supporting, and expanding faculty and student research ...
University of Alaska Anchorage
core  

Electroactive Metal–Organic Frameworks for Electrocatalysis

open access: yesAdvanced Functional Materials, EarlyView.
Electrocatalysis is crucial in sustainable energy conversion as it enables efficient chemical transformations. The review discusses how metal–organic frameworks can revolutionize this field by offering tailorable structures and active site tunability, enabling efficient and selective electrocatalytic processes.
Irena Senkovska   +7 more
wiley   +1 more source

Optimizing Lightning Arrester Selection for 275kV EHV Substations: A Comparison of Overvoltage Analysis with Software and Manual Calculations

open access: yesJurnal Nasional Teknik Elektro
A substation is one of the essential aspects of an electrically interconnected system, especially in a grid utility. Power generation, transmission, and distribution systems always need a continuous power supply to the customer.
Bagus Irawan Saputra   +2 more
doaj   +1 more source

Analysis of Transformer Insulation Risk Due to Back Flashover Lightning on High Voltage Substations by Considering the Effect of Environmental Pollution [PDF]

open access: yesمجله مدل سازی در مهندسی
The improved limiting parameter method of Monte Carlo is used in this study to estimate the impact of back-flashover (BF) due to lightning and provide an evaluation criterion for the insulation risk of the transformer in the high-voltage substation.
Faridoddin Safaei, Mohsen Niasati
doaj   +1 more source

Home - About - Disclaimer - Privacy