Results 11 to 20 of about 11,911 (300)

Optimum feature selection for classification of PD signals produced by multiple insulation defects in electric motors [PDF]

open access: yesScientific Reports
Partial discharges (PD) are initiated in electrical equipment during various points of the equipment’s lifecycle. The intensity of PD defects rises continuously with time, which can lead to insulation degradation and reduced operational life of the ...
Waqar Hassan   +5 more
doaj   +3 more sources

Deep Learning-Based Intelligent Detection Device for Insulation Pull Rod Defects

open access: yesEnergies
This paper proposes a deep learning-based intelligent detection device for insulation pull rod defects, addressing the issues of low detection accuracy, poor timeliness of intelligent analysis, and the difficulty in preserving detection results. Firstly,
Hua Yu   +7 more
doaj   +4 more sources

Research on Online Monitoring of Partial Discharge of Insulation Defects in Air Switchgear Based on Characteristic Gases

open access: yesApplied Sciences
Air switchgear is an important power equipment in the transmission, transformation, and distribution process of the power system. Insulation defects can lead to partial discharge, which is one of the primary causes of air switchgear failure.
Yi Tian   +3 more
doaj   +4 more sources

ONLINE TECHNOLOGICAL MONITORING OF INSULATION DEFECTS IN ENAMELED WIRES

open access: yesElectrical engineering & Electromechanics, 2017
In this paper the authors used non-destructive technological monitoring of defects insulation enameled wire with poliimid polymer. The paper is devoted to the statistical method for processing, comparison and analysis of results of measurements of ...
V. M. Zolotaryov   +4 more
doaj   +5 more sources

Identification of XLPE cable insulation defects based on deep learning

open access: yesGlobal Energy Interconnection, 2023
The insulation aging of cross-linked polyethylene (XLPE) cables is the main reason for the reduction in cable life. There is currently a lack of rapid and effective methods for detecting cable insulation defects in power-related sectors.
Tao Zhou   +5 more
doaj   +3 more sources

Effect of Interface Defects on the Electric–Thermal–Stress Coupling Field Distribution of Cable Accessory Insulation

open access: yesEnergies
The combined insulation interface of a high-voltage cable and accessories is the weakest part of a cable system. In this paper, the parameters of the dielectric constant, thermal conductivity, and elastic modulus of cross-linked polyethylene (XLPE) and ...
Xu Lu   +6 more
doaj   +2 more sources

IDENTIFICATION OF TECHNOLOGICAL DEFECTS IN HIGH-VOLTAGE SOLID INSULATION OF ELECTRICAL INSULATION STRUCTURES ON THE CHARACTERISTICS OF PARTIAL DISCHARGES

open access: yesElectrical engineering & Electromechanics, 2019
Introduction. High-voltage insulation systems always have some background level of the partial discharges, which does not have any significant effect on the life of the electrical insulation design.
G. V. Bezprozvannych   +3 more
doaj   +2 more sources

A curvature-adaptive flexible capacitive sensing system for early detection of corrosion under insulation in long-distance thermal pipelines [PDF]

open access: yesScientific Reports
Corrosion under insulation (CUI) poses a significant threat to the integrity and safety of long-distance thermal pipelines. However, conventional non-destructive testing (NDT) methods struggle to achieve early-stage detection of CUI while effectively ...
Tao Zeng   +3 more
doaj   +2 more sources

On the Identification of Insulation Defects Supporting Partial Discharges

open access: yes2014 AEIT Annual Conference - From Research to Industry: The Need for a More Effective Technology Transfer (AEIT), 2014
The identification of defects supporting Partial Discharge (PD) phenomena in insulation systems of HV machines and components, is a fundamental requirement of any diagnostic procedure because different defect typologies can affect in different ways the ...
CONTIN, ALFREDO, Alfredo Contin
core   +3 more sources

The impact of temperature on intermittent discharge characteristics of solid insulation defects inside GIS

open access: yes电力工程技术
Given the frequent missing and false alarms of partial discharge insulation defects in on-site gas insulated substation (GIS), intermittent discharge characteristics tests are conducted in this article to study the discharge characteristics of common ...
ZHANG Guozhi   +4 more
doaj   +2 more sources