Identification of XLPE cable insulation defects based on deep learning
The insulation aging of cross-linked polyethylene (XLPE) cables is the main reason for the reduction in cable life. There is currently a lack of rapid and effective methods for detecting cable insulation defects in power-related sectors.
Tao Zhou +5 more
doaj +3 more sources
Optimum feature selection for classification of PD signals produced by multiple insulation defects in electric motors [PDF]
Partial discharges (PD) are initiated in electrical equipment during various points of the equipment’s lifecycle. The intensity of PD defects rises continuously with time, which can lead to insulation degradation and reduced operational life of the ...
Waqar Hassan +5 more
doaj +2 more sources
Multiple detections of insulation defects partial discharge in gas-insulated equipment
Gas-insulated equipment is an important part of the power system owing to its advantages of small footprint, large transmission capacity, and high reliability.
Fanjun Kong +7 more
doaj +2 more sources
Deep Learning-Based Intelligent Detection Device for Insulation Pull Rod Defects
This paper proposes a deep learning-based intelligent detection device for insulation pull rod defects, addressing the issues of low detection accuracy, poor timeliness of intelligent analysis, and the difficulty in preserving detection results. Firstly,
Hua Yu +7 more
doaj +3 more sources
Analysis of the deterioration process of DC XLPE cable with protrusion defect based on the development of partial discharge. [PDF]
High-voltage direct current (HVDC) cables are essential for long-distance power transmission, particularly in renewable energy applications. Cross-linked polyethylene (XLPE) insulation is commonly used in these cables, but protrusion defects that occur ...
Yunjie Zhou +5 more
doaj +2 more sources
Features of monitoring extra large partial discharge in high voltage insulators
THE PURPOSE of the described study is to study the effect of partial discharges on the physical state of previously detected defects in high-voltage insulators.
D. A. Ivanov
doaj +1 more source
Defects in Insulating Materials [PDF]
AbstractThis issue of physica status solidi (c) is dedicated to papers submitted during the 2012 International Conference on Defects in Insulating Materials (ICDIM 2012), which was held in Santa Fe, NM USA on June 24–29, 2012. ICDIM 2012 is the 18th edition of a series that began in 1956 at Argonne, USA, with the meeting “Color Centers in Alkali ...
Chris Stanek +3 more
openaire +1 more source
Partial discharge (PD) is the main feature that effectively reflects the internal insulation defects of gas-insulated switchgear (GIS). It is of great significance to diagnose the types of insulation faults by recognizing PD to ensure the normal ...
Qianzhen Jing +4 more
doaj +1 more source
Identifying Prognostic Indicators for Electrical Treeing in Solid Insulation through PD Analysis [PDF]
This paper presents early results from an experimental study of electrical treeing on commercially available pre-formed silicone samples. A needle-plane test arrangement was set up using hypodermic needles.
Binti Ab Aziz, Nur Hakimah +2 more
core +5 more sources
Insulator Defect Detection Technology Research [PDF]
Nonlinear composite insulator voltage distribution is big, the umbrella skirt interval is small, this brought difficulty to defect inspection of composite insulator. Article is studied based on electric power within the composite insulator type defect inspection technology, the principle of uv pulse method, ultrasonic method and electric field method ...
Yupeng Wang +4 more
openaire +1 more source