Results 21 to 30 of about 62,374 (306)

Detection Sensitivity of Input Impedance to Local Defects in Long Cables

open access: yesIEEE Access, 2020
Broadband impedance spectroscopy (BIS) has become a new method for detecting cable insulation defects, but the sensitivity of this method to local defects in cables has not been fully studied.
Wenxia Pan   +5 more
doaj   +1 more source

Localization of HV Insulation Defects Using a System of Associated Capacitive Sensors

open access: yesEnergies, 2023
The issue of detecting and locating defects generating partial discharges (PDs) is very important for the proper functioning of power grids. Despite the existence of many localization methods, both very large and relatively small objects are still a ...
Krzysztof Walczak
doaj   +1 more source

Detection of insulation defects in the wire through measuring changes in its capacitance [PDF]

open access: yes, 2018
The paper describes the technique to detect local wire insulation defects through measuring the wire capacitance. The operating principle of the CAP-10 device is explained.
Ryumkin, A. V.   +1 more
core   +1 more source

Modelling of Electrical Discharge Processes for Optimization of Corona-Protection System of High Voltage Rotating Machines Insulation [PDF]

open access: yesProblems of the Regional Energetics, 2020
The aim of this work is to study the influence of technological defects in stator windings electri-cal insulation system on the inception of partial discharges in the stator slot of air-cooled electric rotating machines.
Andreev A.M.   +5 more
doaj   +1 more source

Determination of sensitivity for in-process control of cable product insulation [PDF]

open access: yes, 2015
This article presents current methods of cable insulation control. The new method which allows to improve reliability of cable insulation control was offered.
Redko, Lyudmila Anatolevna   +3 more
core   +1 more source

Partial Lattice Defects in Higher-Order Topological Insulators [PDF]

open access: yesPhysical Review Letters, 2019
Nonzero weak topological indices are thought to be a necessary condition to bind a single helical mode to lattice dislocations. In this work we show that higher-order topological insulators (HOTIs) can, in fact, host a single helical mode along screw or edge dislocations (including step edges) in the absence of weak topological indices.
Queiroz, Raquel   +4 more
openaire   +3 more sources

A Classification System for Insulation Defect Identification of Gas-Insulated Switchgear (GIS), Based on Voiceprint Recognition Technology

open access: yesApplied Sciences, 2020
Insulation defects that occur in gas-insulated switchgear (GIS), which is one of the most important types of equipment in the power grid, can lead to serious accidents.
Weijia Yao   +4 more
doaj   +1 more source

LDA-Based Model for Defect Management in Residential Buildings [PDF]

open access: yes, 2019
This study systematically analyzes various defect patterns that occur during the warranty period of residential buildings using the loss distribution approach (LDA).
안용한
core   +1 more source

Influence of Deformed Corrugated Aluminum Sheath on the Electric Field of Extruded Insulation DC Cable

open access: yesZhongguo dianli, 2020
In order to determine the possible damage to the cable insulation structure by deformed corrugated aluminum sheath of HVDC cable and its influence on the electrical performance during operation, thermal expansion test and radial pressure test were ...
Hongliang ZHANG   +6 more
doaj   +1 more source

A STATISTICAL MODEL OF MONITORING OF INSULATION BREAKDOWN VOLTAGE STABILITY IN THE PROCESS OF ENAMELED WIRES PRODUCTION

open access: yesElectrical engineering & Electromechanics, 2019
This paper is devoted to non- destructive technological monitoring of defects of insulation of enameled wires with poliimid polymer. The authors present a statistical method for processing, comparison and analysis of outcomes of measurements of ...
A. G. Gurin   +5 more
doaj   +1 more source