Results 141 to 150 of about 308,801 (188)
Some of the next articles are maybe not open access.
Impacts of corona rings on the insulation performance of composite polymer insulator strings
IEEE Transactions on Dielectrics and Electrical Insulation, 2015Corona rings can improve the insulation performance of insulator strings because of their electric field grading property or can decrease the insulation performance due to their arc clearance reduction property. The resulting insulation performance of the string which is under the influence of those two conflicting effects depends on the corona ring ...
İlhan, Suat +2 more
openaire +3 more sources
Influence of attachment of insulating string on AC flashover strength of insulator
Proceedings of the Twenty-First Symposium on Electrical Insulating Materials, 2005The relation between ac flashover voltage (ACFOV) and an attachment of nylon string on the insulator surface is studied in air by using a PMMA insulator which has a backside electrode. The measurements show that the ACFOV is decreased by the attachment of the string.
E. Ishikawa +3 more
openaire +1 more source
Research on the Detection of Faulty Insulator Strings
Advanced Materials Research, 2011A series of experiments on the corona current pulse appearing on insulators under various contamination conditions with AC voltage of different amplitude are described. The corona current pulses were found to follow the Gaussian distribution and can be used to distinguish the faulty insulators from normal insulator strings in transmission line.
Yi Xiong Nie +2 more
openaire +1 more source
Investigation of single unit flashovers in HVDC insulator strings
IEEE Transactions on Power Delivery, 1996In HVDC transmission lines, a special phenomenon, so-called single unit flashover, is observed under some special conditions. Only one or two insulator units repeat flashovers, not resulting in an overall flashover along the string. However, higher magnitudes of audible noise, radio and television interferences may give a serious problem.
Kouichi Ishikawa +5 more
openaire +1 more source
Reduction of AC flashover strength by the attachment of insulating strings on the insulator surfaces
Electrical Engineering in Japan, 1992AbstractAC flashover voltage in air (ACFOV) decreases when nylon string is attached on the PMMA insulator surface which has a backside electrode. The decrease in ACFOV by the attachment is explained by the generation and the propagation of the negative surface leader along the string.
Yoshiaki Yamano +3 more
openaire +1 more source
The Analysis and Simulation of Voltage Distribution Over String Insulators Using Matlab/Simulink
String insulators are generally used to insulate and carry the line conductor in the overhead power transmission lines. The number of insulator units depends on the operation voltage and other factors such as contamination, mechanical strength, lightning,
Ercan izgi, Selim Ay
exaly +2 more sources
Electrical Engineering, 1934
A series of tests on suspension insulators For power transmission lines is described this paper, and results are given which should be of interest to design engineers. The tests made included long-time Fatigue tests, the distribution of voltage over the insulator string, and the flashover voltage when some of the units are electrically defective.
openaire +1 more source
A series of tests on suspension insulators For power transmission lines is described this paper, and results are given which should be of interest to design engineers. The tests made included long-time Fatigue tests, the distribution of voltage over the insulator string, and the flashover voltage when some of the units are electrically defective.
openaire +1 more source
Identifying faulty insulator strings by detecting insulator corona pulse current
POWERCON '98. 1998 International Conference on Power System Technology. Proceedings (Cat. No.98EX151), 2002The resolution to identify faulty insulator strings by detecting insulator corona current pulse was investigated in our laboratory. The influences of some facts on the detection resolution were also discussed, including the characteristics of insulators close to line, the resistance of faulty insulators, the locations of the faulty insulators, and the ...
null Cheng Rong Li +4 more
openaire +1 more source
DEVELOPMENT OF SOFTWARE FOR SELECTING INSULATORS AND INSULATOR STRINGS
Proceedings CIRED24The role of overhead distribution lines for 10 kV, 20 kV and 35 kV in the functioning of the distribution system is fundamental. One of the parts of the overhead lines consists of insulators with equipment that have the role of separating the parts of the lines that are under voltage from those that are not and accept the weight of the conductor in all
Milica Vlaisavljević +2 more
openaire +1 more source
Evaluation of transmission line insulator for I-Type string insulator design
2016 IEEE International Conference on Power and Energy (PECon), 2016Glazed glass cap and pin insulators that have been removed from the transmission line, have electrical characteristics ensuring them to be reused and reinstalled on lower voltage distribution level lines. The electrical properties determination involving insulator resistance, self-capacitance, corona inception voltage and flashover voltage were ...
H. Ahmad +8 more
openaire +1 more source