Results 11 to 20 of about 196,008 (271)
In order to study the influence of tension insulator string’s weight on the sags and tensions of ultra-high voltage (UHV) conductors, full-scale testing and theoretical analysis are carried out. The full-scale testing of sags of a three-span transmission
Gang SONG +3 more
doaj +2 more sources
Mechanism Design of an Insulator Cleaning Robot for Suspension Insulator Strings
Cleaning contaminated insulators is an effective way to protect power transmission lines from accidental power outages caused by flashovers due to wet polluted insulators. Traditional cleaning methods are risky, inefficient, expensive and labor-intensive.
Chang Y(常勇) +4 more
core +3 more sources
Research on the Detection of Faulty Insulator Strings
A series of experiments on the corona current pulse appearing on insulators under various contamination conditions with AC voltage of different amplitude are described.
Yi Xiong Nie +2 more
core +2 more sources
Mechanical Calculation of Flexible Wires of Spans with Different Tensioning Insulator Strings [PDF]
In design activities, technical solutions are practiced, which provide for the use of different tension strings of insulators in a single span. The present paper considers the calculation of the sag and load factors for a span with two different ...
Yu. V. Bladyko
doaj +2 more sources
Development of a system for detecting and locating damaged insulator strings with signals collected at substations [PDF]
This paper presents a novel technique for remotely identifying and locating of damaged insulator strings based on an analysis of noise signals recorded on the ground connection of current transformers installed on transmission line substations.
Renato Massoni Capelini
doaj +2 more sources
In the current study, a multi-arc predicting model for DC critical flashover voltage of iced and pre-contaminated long insulator strings under low atmospheric pressure is developed.
Zhijin Zhang +5 more
doaj +2 more sources
Discharge Phenomenon of a 500 kV Double Tension Porcelain Insulator String
The mechanism of this phenomenon was studied with a double tension porcelain insulator strings in a 500 kV converter station. Experiments including resistance testing and cross-sectional staining were conducted, and a simulation model of double insulator
Yang CHENG +6 more
doaj +2 more sources
Insulator strings with several material and profiles are very common in overhead transmission lines. However, the electric field and voltage distribution of insulator string is uneven which may easily lead to corona, insulators’ surface deterioration and
E. Akbari +3 more
doaj +1 more source
The Impact of Transmission Line Modeling on Lightning Overvoltage
In most of the work that investigates the backflashover phenomenon due to direct lightning strikes, using EMT-type simulators, transmission lines are represented by the J. Marti model and the ground effect is computed employing J. R.
Jaimis Sajid Leon Colqui +4 more
doaj +1 more source
Topological insulators and superconductors from string theory [PDF]
13 pages, 3 figures;references ...
Ryu, Shinsei, Takayanagi, Tadashi
openaire +2 more sources

